Electrical Specifications: Charge Mode
975-0468-01-01
2–3
Electrical Specifications: Charge Mode
AC Input
Operating voltage range
95–135 Vac
Nominal current
12Aac at 55A charge, 120 Vac in
Nominal frequency
60 Hz
DC Output
Nominal voltage
12.0 Vdc
Min battery voltage for charging
0.0 Vdc
Max output voltage
14.4 Vdc
Nominal output current
User selectable:
5 A, 15 A, 35 A, 55 A
Charger current derating
Automatically reduce charger
current as internal temperature
exceeds 80 °C, and input Vac
approaches low transfer.
Efficiency at nominal output
≥
78%
Other
Battery type settings
Flooded (default), Gel, AGM, or
Fixed (13.5V)
Charge algorithms
Three stages (Bulk, Absorption,
and Float)
Independent battery banks