A–2
975-0390-01-01
Electrical Specifications: Inverter Mode
DC Input
Freedom HF 1000
Freedom HF 1800
Operating voltage range
10.5V–15.5V
10.5V–15.5V
Safe non-operating voltage range
0–16 Vdc
0–16 Vdc
Normal voltage
12.5V
12.5V
Nominal current at full load
100A
180A
AC Output
Freedom HF 1000
Freedom HF 1800
Output voltage
115 Vac
115 Vac
Continuous power
1.0kW @ 25 °C
1.8kW @ 25 °C
Surge power
17A
(2kW for 200 ms)
30A
(3.6kW for 300 ms)
Max short-circuit current
55A peak
55A peak
Frequency
60 Hz
60 Hz
Wave shape
Modified Sinewave
Modified Sinewave
Power derating above 40 °C ambient
temp
See
“Invert Power Derating vs. Ambient
Temperature” on page A–6
.
Peak efficiency
≥
87%
≥
87%
Full load efficiency
≥
80%
≥
80%
Other
Freedom HF 1000
Freedom HF 1800
No load input power (producing
output voltage)
≤
10W
≤
10W
Off mode current draw
≤
1mA
≤
1mA