12.

£

Test FSW inverter.

l

Enable FSW inverter through the ComBox tablet, or using the button on the front of the FSW unit.

l

Run your desired AC appliance to make sure there is AC output from the inverter.

l

Monitor the inverter status on the ComBox tablet.

13.

£

Test FSW charger.

l

Apply AC shore power to the FSW AC input.

l

Ensure FSW charger is enabled on the ComBox tablet. After a brief moment to qualify AC shore power, the FSW
should begin charging.

l

If you already have AC appliances running on inverter power, they should not be interrupted as FSW
automatically and seamlessly transfers shore power to support AC loads.

l

Monitor the FSW charger status on the ComBox tablet.

l

Also, monitor the battery SoC gauge on the remote panel to ensure the battery information is displayed correctly
there.

14.

£

Test full load operation.

l

Run DC and AC loads on the vehicle for one complete discharge cycle of the battery as a system burn-in test.

l

Pay attention to any abnormal operations as well as overheating on all wiring and connections.

15.

£

Fully charge the battery.

l

After testing the system at full load condition, turn off all DC and AC loads. Charge the Li-ion battery until it
reaches 100% SoC.

16.

£

Safely power down the system.

l

Shut down and de-energize the system.

l

Remove AC shore power.

l

Remove all DC and AC loads.

l

Turn off the vehicle’s engine ignition.

l

Check the Balmar regulator display is off.

l

Turn off the BMS using the the Reset button on the remote panel or by using its Power button. If the vehicle is to
be stored for longer than 3 months, refer to the Xantrex Battery Storage and Maintenance Guide (975-1005-01-
01) for more information.

Copyright © 2019 Xantrex LLC. All Rights Reserved.

All trademarks are owned by Xantrex LLC and its affiliates.

Exclusion for Documentation

UNLESS SPECIFICALLY AGREED TO IN WRITING, SELLER

(A) MAKES NO WARRANTY AS TO THE ACCURACY, SUFFICIENCY OR SUITABILITY OF ANY TECHNICAL OR OTHER INFORMATION
PROVIDED IN ITS MANUALS OR OTHER DOCUMENTATION;

(B) ASSUMES NO RESPONSIBILITY OR LIABILITY FOR LOSSES, DAMAGES, COSTS OR EXPENSES, WHETHER SPECIAL, DIRECT,
INDIRECT, CONSEQUENTIAL OR INCIDENTAL, WHICH MIGHT ARISE OUT OF THE USE OF SUCH INFORMATION. THE USE OF ANY SUCH
INFORMATION WILL BE ENTIRELY AT THE USER’S RISK; AND

(C) REMINDS YOU THAT IF THIS MANUAL IS IN ANY LANGUAGE OTHER THAN ENGLISH, ALTHOUGH STEPS HAVE BEEN TAKEN TO
MAINTAIN THE ACCURACY OF THE TRANSLATION, THE ACCURACY CANNOT BE GUARANTEED. APPROVED CONTENT IS CONTAINED
WITH THE ENGLISH LANGUAGE VERSION WHICH IS POSTED AT http://www.xantrex.com.

Contact Information

Telephone

:

+1-800-670-0707 / +1-408-987-6030

Email

:

[email protected],
http://www.xantrex.com/power-products-support/

Web

:

http://www.xantrex.com

976-0361-01-01 Rev B

Copyright © 2019 Xantrex LLC. All Rights Reserved

4

Freedom e-GEN System End-of-Line Checklist

Reviews: