4–8
975-0467-01-01
Operating During Transition Between Shore Power and
Inverter Mode
The
Freedom HW
’s advanced power management is capable of
transitioning power from an AC source to DC source within a fraction of
a second and vice-versa.
The
Freedom HW
automatically detects when shore power is present and
when it becomes unavailable or when shore power drops to less than 95
Vac.
Transitioning from Shore Power to Inverter Mode
When the unit is operating in shore power mode and shore power is lost,
the
Freedom HW
has less than 30 ms (milliseconds) to switch to inverter
mode and start drawing power from the battery.
The Status LED will turn from solid or flashing GREEN to a solid
YELLOW.
Transitioning from Inverter Mode to Shore Power
When the unit is operating in inverter mode and shore power becomes
available, the
Freedom HW
begins a 20-second countdown to verify the
stability of the shore power. If shore power remains stable within 20
seconds, at the end of the countdown, the
Freedom HW
has less than 30
ms (milliseconds) to switch to shore power mode and start drawing power
from the AC source.
The Status LED will turn from solid YELLOW to flashing YELLOW
during the 20-second countdown, then turn to GREEN when battery
power is transitioned successfully to shore power.
Summary of Contents for ENERGY HW 1000
Page 1: ...Freedom HW 1000 Inverter Charger Owner s Guide ...
Page 2: ......
Page 3: ...Freedom HW 1000 Inverter Charger Owner s Guide ...
Page 12: ...x ...
Page 16: ...Contents xiv 975 0467 01 01 ...
Page 18: ...xvi ...
Page 20: ...xviii ...
Page 24: ...1 4 ...
Page 30: ...2 6 ...
Page 38: ...3 8 ...
Page 64: ...5 12 ...
Page 72: ...A 8 ...
Page 78: ...WA 6 ...
Page 79: ......