8

975-0305-01-01

Warranty and Return Information

If your vehicle is within its factory warranty period:

The warranty for this product is covered under your vehicle's express warranty, please 
contact your vehicle manufacturer's owner services department for technical support and 
warranty service.

If your vehicle is out of its factory warranty period:

If the warranty period for your Xantrex AC to DC Converter has expired, if the unit was 
damaged by misuse or incorrect installation, if other conditions of the warranty have not 
been met, or if no dated proof of purchase is available, your unit may be serviced or 
replaced for a flat fee.
To return your Xantrex AC to DC Converter for out of warranty service, contact Xantrex 
Customer Service at 1-360-925-5097 for a Return Material Authorization (RMA) number.
Payment options such as credit card or money order will be explained by the Customer 
Service Representative. In cases where the minimum flat fee does not apply, as with 
incomplete units or units with excessive damage, an additional fee will be charged. If 
applicable, you will be contacted by Customer Service once your unit has been received.

DC Output

XADC-40

XADC-60

XADC-80

Recommended battery bank size

220 Ah

220 Ah

400 Ah

Output current

40 Adc

60 Adc

80 Adc

Current limit (maximum)

44A

64 A

84 A

Nominal output voltage

13.5 Vdc (float charge)

14.2 Vdc (bulk/absorption charge)

Min. output voltage

0 V

Load regulation

a

a.Load regulation is the converter's ability to maintain a constant output voltage as the load
current changes. 

1.5% at terminals of XADC

Line regulation

b

b. Line regulation is the converter's ability to maintain a constant output voltage as the line
(input) voltage changes. 

1.5%

No load voltage accuracy

0.1 Vdc

Efficiency at nominal output

≥ 

85%

Battery draw when turned off

< 2 mA

Towable-OEM-40-60-80A.book  Page 8  Monday, March 5, 2007  12:15 PM

Summary of Contents for 40 A

Page 1: ...Xantrex AC to DC Converter Manual Type 40 A XADC 40 60 A XADC 60 80 A XADC 80 Owner s Guide Towable OEM 40 60 80A book Page i Monday March 5 2007 12 15 PM...

Page 2: ...Towable OEM 40 60 80A book Page ii Monday March 5 2007 12 15 PM...

Page 3: ...Xantrex AC to DC Converter Owner s Guide Towable OEM 40 60 80A book Page i Monday March 5 2007 12 15 PM...

Page 4: ...March 2007 Xantrex International All rights reserved Exclusion for Documentation UNLESS SPECIFICALLY AGREED TO IN WRITING XANTREX TECHNOLOGY INC XANTREX A MAKES NO WARRANTY AS TO THE ACCURACY SUFFICI...

Page 5: ...bleshoot the XADC Organization This Guide is organized into two chapters and one appendix Features Chapter 1 introduces the Xantrex AC to DC Converter shows where the major components are and lists th...

Page 6: ...he XADC 80 when it is being referenced individually When the Xantrex XADC 40 XADC 60 and XADC 80 are being referenced together they will be referred to as the XADC Related Information You can find mor...

Page 7: ...ction 5 Do not disassemble the XADC It contains no user serviceable parts and attempting to service it will void your warranty See Warranty for instructions on obtaining service Attempting to service...

Page 8: ...arts and could cause an explosion 5 Remove all metal items like rings bracelets and watches when working with lead acid batteries Lead acid batteries produce a short circuit current high enough to wel...

Page 9: ...o provide reasonable protection against harmful interference when the equipment is operated in a residential environment This equipment generates uses and can radiate radio frequency energy and if not...

Page 10: ...C DC Distribution Panel 2 2 Operation and Troubleshooting Switching the XADC On and Off 5 Maintenance 5 Troubleshooting Reference 6 A Specifications Mechanical Specifications 7 Electrical Performance...

Page 11: ...n Panel Special Features The XADC has many convenient features Current limiting over temperature protection input under voltage protection and input over voltage protection to give you worry free safe...

Page 12: ...A Part Number 810 0030 00 XADC P30 eight output breakers 50A Part Number 810 0050 00 XADC P50 10 output breakers In each configuration there are also 11 unassigned DC fuses and four reserved fuses for...

Page 13: ...designation label 3 Removable AC DC Distribution Panel faceplate service technician only 4 AC breakers not included 5 Screw for removing AC DC panel faceplate service technician only 6 Screw for remo...

Page 14: ...4 Towable OEM 40 60 80A book Page 4 Monday March 5 2007 12 15 PM...

Page 15: ...C loads should be Littelfuse Type 257 or equivalent and the maximum allowed fuse for the DC loads is 20 A Breakers for the AC side should be MAIN Cutler Hammer Bryant Westinghouse Type BR Series and I...

Page 16: ...are damaged or not installed AC input breaker open Short circuit in one or more of the load circuits Internal temperature too hot Something may be preventing the fan from turning The unit has a safet...

Page 17: ...nit may shut down Length 11 13 16 in 300 0 mm Width 7 1 8 in 180 0 mm Height 4 3 4 in 120 0 mm AC Input XADC 40 XADC 60 XADC 80 Input current at rated output 6 Aac 9 Aac 12 Aac Nominal input voltage 1...

Page 18: ...credit card or money order will be explained by the Customer Service Representative In cases where the minimum flat fee does not apply as with incomplete units or units with excessive damage an additi...

Page 19: ...Towable OEM 40 60 80A book Page 9 Monday March 5 2007 12 15 PM...

Page 20: ...Xantrex Technology Inc www xantrex com 975 0305 01 01 Printed in China Towable OEM 40 60 80A book Page 10 Monday March 5 2007 12 15 PM...

Reviews: