background image

 

                              Application Advisory 

*DATE* 

 

 

Page 4 of 8 

The ZPR68-10 will respond to any IR command by returning data via the serial port. The 
response occurs approximately one second after the last IR command is received. Data 
is returned only for the zone or zones which have received an IR command. Global IR 
commands will cause data to be returned for all zones. An "empty" global IR command 
consisting of the GLOBAL button followed by the ADJ-OFF button will cause data to be 
returned for all zones without causing anything to change.  
   

DATA FORMAT  

Data is sent as a string of ASCII characters. The first string in any group of strings, is 
preceeded by a line-feed (0Ah), a carraige-return (0Dh) and a bell (07h) and each string 
is followed by a line-feed (0Ah) and a carraige-return (0Dh). If more than one string is 
sent, the second and subsequent strings are preceeded by a bell (07h) and each string 
is followed by a line-feed (0Ah) and a carraige-return (0Dh).  

Each string consists of 13 data fields. Each data field consists of one, two or three ASCII 
data characters followed by a tab (09h).The order of the fields in each string is as 
follows:  
   
   

FIELD 

RANGE 

RANGE IN ASCII CODE 

ZONE 01-15 

30h31h-31h35h 

INPUT 01-08 

30h31h-30h38h 

TRIM SETTING  00-06 

30h30h-30h36h 

VOLUME 00-40  30h30h-34h30h 

BALANCE P/S  10L-00C-10R  31h30h4Ch-30h30h43h-31h30h52h

BALANCE 10L-00C-10R 

31h30h4Ch-30h30h43h-31h30h52h

TREBLE P/S 

00-06-12 

30h30h-30h36h-31h32h 

TREBLE 00-06-12 

30h30h-30h36h-31h32h 

BASS P/S 

00-06-12 

30h30h-30h36h-31h32h 

BASS 00-06-12 

30h30h-30h36h-31h32h 

STATUS 

0, 1 

30h, 31h 

MUTE 

0, 1 

30h, 31h 

VOLUME MAX  00-40 

30h30h-34h30h 

The ZONE field indicates which zone is being reported by the string. The string reports 
the INPUT selection, the volume level TRIM setting (see page 265 of the Xantech 
Applications Manual 1998 or the ZPR68-10 Instructions), the VOLUME setting, the 
BALANCE PreSet setting, the BALANCE setting, the TREBLE PreSet setting, the 
TREBLE setting, and the BASS PreSet setting, the BASS setting. The STATUS field 
indicates the condition of the STATUS terminal on the four-pin ZONE CONTROL - IR 
INPUT connector. The MUTE field is not a simple indications of the IR MUTE function. It 

Summary of Contents for ZPR68-10

Page 1: ...ndently of all other functions and is intended for use as an indicator of some function external to the ZPR68 10 such as a warning device Third the volume can now be incremented or decremented via the RS232 serial port The new data display mode causes the ZPR68 10 to send status data to any device connected to the serial port whenever an IR command is received This data can be displayed on a monit...

Page 2: ...set to The 01 indicates that we want to know something about output zone 1 The V indicates that we are interested in the volume level The ZPR68 10 responds that the level is 25 And finally the CR indicates that the data bits exchanged are correct If there is a communications problem the ZPR68 10 will respond with a CR QUERIES The output zones on a ZPR68 10 are factory preset 01 through 06 and EXP9...

Page 3: ... query the status 01C it will return an N if the status is off or a Y if the status is on If you query the mute 01M it will return an N if the mute is off In other words the mute is off if the audio is on The query will return a Y if the mute is on the audio is off DATA QUERY The DATA query causes the ZPR68 10 to return a string of ASCII characters as outlined below Type Z01 for the data string fo...

Page 4: ...ach data field consists of one two or three ASCII data characters followed by a tab 09h The order of the fields in each string is as follows FIELD RANGE RANGE IN ASCII CODE ZONE 01 15 30h31h 31h35h INPUT 01 08 30h31h 30h38h TRIM SETTING 00 06 30h30h 30h36h VOLUME 00 40 30h30h 34h30h BALANCE P S 10L 00C 10R 31h30h4Ch 30h30h43h 31h30h52h BALANCE 10L 00C 10R 31h30h4Ch 30h30h43h 31h30h52h TREBLE P S 0...

Page 5: ...ncrement the volume of zone 5 one 2dB step type 05LU To decrement the volume of zone 5 one 2dB step type 05LD There are two ways to mute the audio without affecting the video First the volume can be set to zero by sending 04V00 To return to the previous volume level type the original volume level command 04V40 again The second way is to use the Q quiet command Type 04QY to quiet the zone and 04QN ...

Page 6: ... characters as outlined in the DATA QUERY section Type Z00 for the data string for all zones Note that the DATA query does not require a or an To query the flag type A A Y will be returned if the flag has been set or an N will be returned if it has been reset Note that an is not used with this query Global queries except for data and flag are not supported 2 POWER SHUTDOWN RECOVERY All settings ar...

Page 7: ...llow the procedure outlined below TO SET THE ZONE NUMBER 1 Connect an IR receiver to that zone 2 Set the switches on the rear of a Xantech RC68 or RC68 Programmer to FE 3 Using the table select the button for the number desired For example to set the zone to respond to 03 press the button marked 90 The zone now is identified as 03 4 Be sure to reset the switches on the programmer to anything other...

Page 8: ...RC 68 01 80 20 48 02 10 03 90 64 01 00 00 05 C0 06 50 07 D0 68 41 04 40 09 A0 10 30 11 B0 72 21 08 20 13 E0 14 70 15 F0 76 61 12 60 17 88 18 18 19 98 80 09 16 08 25 A8 26 38 27 B8 88 29 24 28 29 E8 30 78 31 F8 92 69 28 68 21 C8 22 58 23 D8 84 49 77 E1 81 89 85 C9 89 A9 93 E9 78 71 82 19 86 59 90 39 94 79 79 F1 83 99 87 D9 91 B9 95 F9 ...