Application Advisory
*DATE*
Page 4 of 8
The ZPR68-10 will respond to any IR command by returning data via the serial port. The
response occurs approximately one second after the last IR command is received. Data
is returned only for the zone or zones which have received an IR command. Global IR
commands will cause data to be returned for all zones. An "empty" global IR command
consisting of the GLOBAL button followed by the ADJ-OFF button will cause data to be
returned for all zones without causing anything to change.
DATA FORMAT
Data is sent as a string of ASCII characters. The first string in any group of strings, is
preceeded by a line-feed (0Ah), a carraige-return (0Dh) and a bell (07h) and each string
is followed by a line-feed (0Ah) and a carraige-return (0Dh). If more than one string is
sent, the second and subsequent strings are preceeded by a bell (07h) and each string
is followed by a line-feed (0Ah) and a carraige-return (0Dh).
Each string consists of 13 data fields. Each data field consists of one, two or three ASCII
data characters followed by a tab (09h).The order of the fields in each string is as
follows:
FIELD
RANGE
RANGE IN ASCII CODE
ZONE 01-15
30h31h-31h35h
INPUT 01-08
30h31h-30h38h
TRIM SETTING 00-06
30h30h-30h36h
VOLUME 00-40 30h30h-34h30h
BALANCE P/S 10L-00C-10R 31h30h4Ch-30h30h43h-31h30h52h
BALANCE 10L-00C-10R
31h30h4Ch-30h30h43h-31h30h52h
TREBLE P/S
00-06-12
30h30h-30h36h-31h32h
TREBLE 00-06-12
30h30h-30h36h-31h32h
BASS P/S
00-06-12
30h30h-30h36h-31h32h
BASS 00-06-12
30h30h-30h36h-31h32h
STATUS
0, 1
30h, 31h
MUTE
0, 1
30h, 31h
VOLUME MAX 00-40
30h30h-34h30h
The ZONE field indicates which zone is being reported by the string. The string reports
the INPUT selection, the volume level TRIM setting (see page 265 of the Xantech
Applications Manual 1998 or the ZPR68-10 Instructions), the VOLUME setting, the
BALANCE PreSet setting, the BALANCE setting, the TREBLE PreSet setting, the
TREBLE setting, and the BASS PreSet setting, the BASS setting. The STATUS field
indicates the condition of the STATUS terminal on the four-pin ZONE CONTROL - IR
INPUT connector. The MUTE field is not a simple indications of the IR MUTE function. It