background image

 

 

 

   

 

INSTALLATION – SMVID01: Video Sensor Module 

The SMVID01 sensor module provides status feedback by monitoring the composite video 
connection. The sensor head is placed in between and input and output video signal. For instance, 
the sensor head is placed between a video display and a DVD player on the composite video cable.  
 

(1) Plug the 1/8” (3.5mm) mini-plug into the sensing controller (CBCSM1 and MRC platform 

provides power to the sensor module). Sensing controller power should be off. 

(2) Connect the sensor head on the output of the video source. 
(3) Connect the video cables as you would normally do. 
(4) Turn on the video source output. (i.e. ‘power on’ button on a DVD player) 
(5) Verify the SMVID01 LED indicator is ‘on’.  
(6) Turn off the video source output. (i.e. ‘power off’ button on a DVD player) 
(7) Verify the SMVID01 LED indicator is ‘off’. 
(8) If the indicator is not ‘off’, then adjust the sensitivity until the LED just turns off.  
(9) Repeat Steps 4 to 8 until both ‘on’ and ‘off’ conditions are satisfied.  

 
 
 
 

Summary of Contents for SMAUD01

Page 1: ...SMCC01 Contact Closure Sensor Module SMVLT01 AC DC Voltage Sensor Module Each module comes with double sided foam tape and mounting screws Also built into the sensor is a convenient LED light that tur...

Page 2: ...r sees a voltage that stimulated the sensor to the on condition the delay will determine when the sensor returns to the off condition Increase Decrease Delay Clockwise Counter Clockwise Sensitivity Cl...

Page 3: ...ls 1 Plug the 1 8 3 5mm mini plug into the sensing controller CBCSM1 and MRC platform provides power to the sensor module Sensing controller power should be off 2 Connect the sensor head on the output...

Page 4: ...and MRC platform provides power to the sensor module Sensing controller power should be off 2 Connect the sensor head on the output of the video source 3 Connect the video cables as you would normall...

Page 5: ...nnect the power cord as you would normally do 4 Turn on the device connected to the power cord and power the device on 5 Verify the SMMAG01 LED indicator is on 6 Turn off the device connected to the p...

Page 6: ...r can be used to detect red LED lamps only A green colored filter can be used to detect green LED lamps only 1 Plug the 1 8 3 5mm mini plug into the sensing controller CBCSM1 and MRC platform provides...

Page 7: ...satisfied INSTALLATION SMVLT01 AC DC Voltage Sensor Module The SMVLT01 sensor module detects AC or DC voltage between 9 to 24 volts Two wires are connected from the voltage generating source to the s...

Page 8: ...se the power state of a component by detecting the difference in current drawn by the component when it is either ON or OFF and to generate a status signal that can be used to control other equipment...

Reviews: