MRKP2E – REAR CONNECTORS 

 

 

 

Figure 2.4: Rear connector board of MRKP2E Keypad 

 
 
Note: The IR Out feature on this keypad comes disabled from the factory and if 
needed, it should be enabled using the Xantech Universal Dragon 
programming software. 
 
 
 
 

IR

IN

IR

O

U

T

+

1

2

V

D

C

GN

D

GN

D

TO CONTROLLER

IR SENSOR
ENABLE JUMPER
(JP3)

JP3

XANTECH
IR RECEIVER

TO EXPANSION

KEYPAD

 

11 

Installation 

 

The MRKP2E is designed to mount in a UK and EU standard two gang 
electrical back- box (see Specifications sections for details). Typical mounting 
height is 56-60 inches (1.53 meters) from the floor to the bottom of the frame. 
This provides optimum “eye-level” viewing for the largest number of people.  
 
Route the CAT-5 cable from the MX88 into the back of the electrical back-box, 
terminate it with an RJ-45 connector after it is passed through the electrical 
back-box.  Connect it to the appropriate RJ-45 connector on the rear of the 
MRKP2E (“CONTROLLER” for connecting to MX88, or “EXPANSION” if 
connecting to an extension keypad). If using an IR Receiver, strip the ends of 
three conductors of the IR receiver’s cable and insert into the appropriate 
terminals of the IR Input terminal block shown in Figure 3.1.  
 
Once connections are made, mount the MRKP2E into the electrical back-box 
using the two provided screws. Mount the Trim Plate Bracket as shown in the 
Figure 2.5 on next page, and then snap the Screw-less Trim Plate in place.   
 

Note: Do not mount the MRKP2E in the same electrical back- box as high voltage 

devices such as electrical outlets or switches. 

 

Figure 2.5: MRKP2E keypad installation in EU/UK standard  

Two-gang back-box 

 

DUAL-G

ANG

WALL BOX

MOUNTINGSCREWS(M3.5 x 30MM)
Note: Mounting screws are included with
most electrical back-boxes.
Extra mounting screws are also included
with the MRKP2Eproduct in case
the back-box screws are not supplied or
are somehow not suitable for use.

MRKP2E

TRIM PLATE

TWO-GANG 
ELECTRICAL 
BACK-BOX 

MOUNTING SCREWS (M3.5X30MM) 
Note: Mounting screws are included 
with most electrical back boxes. 
Extra mounting screws are also 
included with the MRKP2E product in 
case the back box screws are not 
supplied or are somehow not suitable 
for use. 

Summary of Contents for MRKP2E

Page 1: ...hat could result in a fire or electric shock Care should be taken so that objects do not fall and liquids are not spilled into the appliance through openings in the enclosure Servicing Do not attempt to service these appliances yourself as opening or removing covers may expose you to dangerous voltage or other hazards Refer all servicing to qualified service personnel Damage Requiring Service Thes...

Page 2: ...to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help CAUTION Changes or modifications not expressly approved by...

Page 3: ...display Displays multiple lines of meta data and menu navigation lists Full featured keypad with navigation and select hard buttons Selectable keypad backlight color Includes screwless wall plates in European and UK standard dimensions Quick Plug and Play Installation No PC Software Programming Required Hot Swappable no need to shut down and reset system when upon connection of keypad Supports Xan...

Page 4: ...ce wall plates IR emitters etc Always fully test all actual components to be installed before taking them to the jobsite This will help streamline and expedite any troubleshooting on site in case it becomes necessary 7 Pre Construction In a pre construction installation walls and ceilings are open with no drywall installed This is desirable and allows the installer greater access than in retro fit...

Page 5: ...NT PANEL Figure 2 3 MRKP2E Keypad layout and Main display Notes Tone Control functions of the MRKP2E can be entered by pressing the Next arrow once inside a source control page Please note that each of the three controls can be returned to their center position by tapping the center of each bar Unlike older keypads and due to the unique and streamlined functional set up of the MRKP2E s buttons pre...

Page 6: ...ting to an extension keypad If using an IR Receiver strip the ends of three conductors of the IR receiver s cable and insert into the appropriate terminals of the IR Input terminal block shown in Figure 3 1 Once connections are made mount the MRKP2E into the electrical back box using the two provided screws Mount the Trim Plate Bracket as shown in the Figure 2 5 on next page and then snap the Scre...

Page 7: ...one will require the use of MRC44CB1 and 782ERGPS High Current AC adaptors Please see Important Notes on page 6 and the Specifications page for more details Internal IR Receiver The internal IR receiver is located beneath the keypad s face plate between the POWER and X buttons see Figure 2 3 The internal IR receiver receives IR commands for the MRKP2E and for the MX88 It will also pass thru IR rem...

Page 8: ...N IR OUT 12VDC GND GND TO CONTROLLER IR SENSOR ENABLE JUMPER JP3 JP3 XANTECH IR REPEATER TO EXPANSION KEYPAD IR RECEIVER 15 4 MRKP2E Setup Initial Power up Whenever the MX88 or the keypad itself is reset the MRKP2 will take approximately 1 minute to initialize During most of this period of time with the exception of first 5 seconds the On Standby LED will be illuminated in green as an indication t...

Page 9: ... new firmware and the MRKP2E will return to normal operation After the keypad returns to normal operation it is advisable to reset the entire system by turning the MX88 off and back on Please note that application update is to be performed by factory authorized personnel only and the procedure to do so is not within the scope of this document Other reference documentation Universal Dragon MX88 pro...

Page 10: ... IR flooding is likely cause Disable the built in IR Receiver Consider use of an external IR Receiver see Fig 2 2 and 3 2 19 6 Specifications MRKP2E basic dimensions and cable lengths Front panel dimensions UK Trim Plate 148mm 5 7 8 wide x 88mm 3 7 16 high x 15mm 5 8 deep EU Trim Plate 148mm 5 7 8 wide x 80mm 3 3 8 high x 15mm 5 8 deep Wall cutout Depends on electrical back box used see below Moun...

Page 11: ...20 21 ...

Page 12: ...mitation may not apply to you This warranty gives you specific legal rights You may have additional legal rights that vary from state to state Xantech is a registered trademark of Xantech LLC Legrand is a registered trademark of the Legrand Group Appleby is a trademark of Electrium Sales Limited A Siemens Company Apple and iPad are registered trademarks of Apple Inc All other trademarks are the pr...

Reviews: