background image

IR Receivers

3

12-20-00
Rev. E

PHANTOM POWER CONNECTIONS

Some existing installations may have only 2 wires (such as coax) going to a remote room.  The 480, when
used with a 792-10 Power Module, may be connected for 2-wire phantom power operation as follows:

Additional 480's may be wired in parallel at the 3-terminal block, up to a maximum of three.  More than this
may cause unreliable results.

CAUTION: 

With any of these systems, be sure the 781 power supply is plugged into an un-switched AC

outlet. This maintains the 480 system in "standby" operation so that power-on commands can be sent to
the controlled equipment.

480-00 

Series

IR Receivers

792-10

POWER MODULE

+12V

OUT

IN
GND
+12V
OUT

XANTECH CORPORATION

1 (ON)

0 (OFF)

1   2   3   4   5   6   7   8   9 1 0

ON

1 2 3 4 5 6 7 8 9 10

792-10

Power Module
(In Phantom
High Current mode)

Red (or white)
Stripe

3-Terminal Block (supplied)

2-Conductor
Inter-room Cable
(usually coax)

OUT

+12V

GND

7' Ribbon Cable

To

 

282M 

or

283M 

Emitters

on controlled

equipment

Use wire jumper
between screws as
shown

REMOTE ROOM

HIGH IR

GROUND

EMITTERS

HIGH IR

IN / OUT

781RG

Power Supply

790-00

Connecting Block

MAIN ROOM

®

790

CONNECTING BLOCK

HIGH IR

IN / OUT

480 Series

Reviews: