The OUT port can drive any of the Xantech emitter models in the 282, 283, 284 and 286 series as well as
the 286M shown in Fig. 2.NOTE:  Be sure the Power Supplies, in any of these systems, are plugged into
an unswitched AC outlet.  This maintains the system in "stand-by" operation so that power-on commands
can be sent to the controlled equipment.INSTALLATION (cont'd)

Fig. 3 illustrates another application of the CB12.  In this case it serves as a "break-out" block for the
convenient connection of a 291 IR Receiver to a 3-conductor room-to-room cable in a larger multiroom
system.  You may also use it with any other Xantech quick-connect IR Receiver, such as the 490-30, for
the same purpose.

INSTALLATION NOTES:

1. When used as a "break-out" block, you do not need to connect a power supply to the "PWR" jack on

the CB12.  Power is supplied on the 3-conductor cable coming from the connecting block in the
equipment room.

Also, do not plug an emitter into the "OUT" jack in this case. To do so will prevent operation of the
emitters in the equipment room.

2. When paralleling IR receivers, a maximum of 12 is recommended.  More than this may result in

unreliable operation due to the buildup of IR noise.

3. The Smart Pad™ keypads may be paralleled in larger numbers.  They are not subject to the IR noise

limitation.

4. Mounting:  The CB12 may be mounted on any flat surface using the double-sided adhesive tape

supplied.

Fig. 3

  The CB12 used as a "Break-Out" Block

+12 VDC

IR OUT

GND

780-10

J-BOX RECEIVER

®

Satellite Receiver

AV Receiver

VCR

MAIN ROOM 1, EQUIPMENT CABINET, ETC.

282M

Mouse Emitter

282M

Emitter

283M

Blink IR Emitter

490-30 

Series

Micro Link™
IR Receivers

GND

IR OUT

+12V

780-10

J-Box

IR Receiver

3-Wire
Cable

IR OUT

GND

+12V

480-00

Dinky Link™

IR Receiver

Red
Stripe

GND

IR OUT

+12V

286M

Dual Blink IRs

(to other

controlled

devices)

Hand Held

Remote

CB12

Connecting

Block

OUT

V G S

IR

RCVR

PWR

ROOM 2

291

 IR Receiver

(See Text)

X    X

3-Conductor Room-to-Room Cable

24 to 18 gauge (unshielded OK)

Smart
Pad™

789-44

Connecting Block

To 120 V AC

(unswitched)

782-00

Power

Supply

ROOM 4

ROOM 3

12VDC

+12 VDC

GND

STATUS

IR IN

EMITTERS

IR

RCVR

789-44

CONNECTING BLOCK

®

8-30-00

NOTE:  Be sure the power supplies, in any of these systems, are plugged into an un-switched AC outlet.
This maintains the system in "stand-by" operation so that power-on commands can be sent to the controlled
equipment.