background image

1

Modules & Connecting Blocks

INSTALLATION INSTRUCTIONS

794 & 797

INTERFACE MODULES

The Model 794 or 797 allows any of the Xantech 3-wire IR receivers, keypads and control systems to
connect directly to the serial remote control input jack found on many audio/video components.  This
eliminates the need for attaching an emitter to the front panel of the unit.  The installer, by choosing the
correct model number, suffix number and DIP switch settings, may use these modules to control many
components.

INSTALLATION

• Review all tables 1, 2, & 3  to make sure you select the correct interface.  The model number suffix generally

specifies which INTERFACE CABLE is supplied with the unit (see Tables 1, 2 & 3).

Do Not

 extend the cable supplied with the 794 or 797.  The unit may not operate reliably when a longer

cable is used.

Do Not

 plug the 794 or 797 into anything until all switches are set.

• There are ten DIP switches on the 794 and two on the 797.  When the 794 or 797 is driven by a Model

390 Blast-IR or Model 792 Power Module, switch 

S1

 must be in the 

0

 (off) position.

• The 794 and 797 are designed to supply power to Xantech 3-wire IR Receivers and keypads.  Connect

them directly to the 

IN

GND1

 and 

+12V

 terminals.  The 

IN

 and 

GND1

 terminals may also be connected

to any Xantech emitter output port.

• Use a 781RG  or 782-00 power supply to power the 794 and 797 by plugging them into the 

+12V

 jack.

You may also power them from other Xantech devices in a system by r12 V and Gnd jumper leads
from the other device to the 

+12V

 and 

GND2

 terminals on the 794 and 797.

• If the plug on the 781RG or 782 power supply does not fit the 

+12V

 jack on the 794 or 797, simply remove

the plug and connect the white striped wire to 

+12V

 and the black wire to 

GND2

 on the 794 or 797

terminals.

MODEL 794

• Switch 

S3

 should be in the 

1

 (on) position in most

installations.

• When multiple 794’s are connected, or when ground

loops are encountered, set 

S3

 to the 

0

 (off) position.

• Switch 

S2

, and 

S4

 through 

S10

, should be set ac-

cording to Table 1, page 2.  For products not listed,
contact Xantech Technical  Support.  New versions
are added from time to time.

MODEL 797

• Switch 

S2

 should be in the 

1

 (on) position in most

installations.  When multiple 797’s are connected or
when ground loops are encountered, set 

S2

 to the 

0

(off) position.

• In general, set 

S1

 and 

S2

 according to Table 2, next

page.  For products not listed, contact Xantech Tech-
nical  Support.   New versions are added from time to
time.

OUTPUT

+12V

IR IN

GND1

GND2

+12V

1 (ON)

0 (OFF)

1   2   3   4   5   6   7   8   9 1 0

ON

SENDER/

EMITTER

1 2 3 4 5 6 7 8 9 10

794

UNIVERSAL INTERFACE

Fig. 1

  794-00

IR IN

GND1

GND2

+12V

OUTPUT

+12V

1 (ON)

0 (OFF)

SENDER/

EMITTER

1 2

1   2

ON

797 

SERIES

UNIVERSAL INTERFACE

Fig. 2

  797-00

Reviews: