background image

2

780-10

connections to a Xantech connecting block,
power supply and emitters as shown in the
following illustration of a typical basic system:

While it is possible to make wired connections
without the connecting block, it is not recom-
mended.  The connecting block reduces instal-
lation time, helps to eliminate errors, allows
easy troubleshooting and permits easy system
upgrades later, if needed.

Input connections must be made as illustrated.
To extend the Emitter wires to a more distant
location, you may splice in 2-conductor wire, in the wire gauges mentioned before, as needed.

The 780-10 may be connected to any of the Xantech Connecting Blocks, Controllers, Interface modules,
etc., that have  +12 VDC, INPUT and GND terminals, such as the CB12, 789-44, 791-44, 795-20, 796-20,
794-00, etc.  780-10's may be connected in parallel to these terminals in any combination with other Xantech
3-conductor IR receivers or keypads (12 IR receivers max).

A more advanced system, using 780-10's and a variety of other Xantech IR receivers connected to a 791-
44 Amplified Connecting Block, is shown in 

Fig.3

 below:

Affix the Mini-Emitters, such as the 282, 284,
283 and 286 series, to the IR sensor win-
dows of the controlled equipment in accord
with the instructions that come with them.

Phantom Power Connections

Some existing installations may have only 2
wires (such as coax) going to a remote room.
The 780-10, when used with a 792-10 Power
Module, may be connected for 2-wire phan-
tom power operation as in 

Fig. 4

.

Additional 780's may be wired in parallel at
the 

IN

 and 

GND

 terminals of the 792-10, up

to a maximum of three.  More than this may
cause unreliable results.

CAUTION: 

With any of these systems, be

sure the 781 power supply is plugged into an un-switched AC outlet. This maintains the IR system in
"standby" operation so that power-on commands can be sent to the controlled equipment.

Fig. 3

  780-10 IR Receivers in a Multiroom System

+12 VDC

IR OUT

GND

780-10

J-BOX RECEIVER

+12 VDC

IR OUT

GND

780-10

J-BOX RECEIVER

To 120 V AC
(unswitched)

781RG

Power Supply

791-44

Amplified Connecting Block

283M

 

Blink-IR™

283M

 

Blink-IR™

283M

 

Blink-IR™

VCR

Cassette DecK

GND

IR OUT

+12V

490-00 

Series

Micro Link™

IR Receivers

3-Wire
Cable

IR OUT

GND

+12V

Red
Stripe

3-Wire
Cable

IR OUT

GND

+12V

480-00

Dinky Link™

IR Receiver

Red
(or white)
Stripe

REMOTE ROOM 1

780-10

J-Box IR Receiver

780-10

J-Box IR Receiver

7 Foot 3-Conductor
Cable with Quick
Connect Stereo
Mini Plug

490-30

 

Series

Micro Link™
IR Receivers

MAIN ROOM, EQUIPMENT AREA, ETC.

REMOTE ROOM 2

REMOTE ROOM 3

REMOTE ROOM 4

GND

IR OUT

+12V

3-Conductor
Room-to-
Room Cables
(Home Runs)

283M

 

Blink-IR™

Mouse Emitter

283M

 

Blink-IR™

Satellite Receiver

A/V 

Receiver

CD Changer

+ 1 2   V D C

G N D

EMITTERS

12 VDC

HIGH

IR

OUT

S TAT U S

I R   I N

IR

RCVR

791-

44

AMPLIFIED

CONNECTING BLOCK

®

Fig. 4

  780-10 IR Receiver Wired for Phantom Power Operation

+12 VDC

IR OUT

GND

780-10

J-BOX RECEIVER

792-10

POWER MODULE

+12V

OUT

IR IN
GND
+12V
OUT

XANTECH

1  (ON)

0  (OFF)

1   2   3   4   5   6   7   8   9 1 0

ON

1 2 3 4 5 6 7 8 9 10

792-10

Power Module

(In Phantom

High Current Mode)

2-Conductor
Inter-room
Cable
(usually coax)

To

 

282M 

or

283M 

Emitters

on controlled

equipment

Use jumper wire
between IR OUT
and GND screws
as shown

SIGNAL

GROUND

EMITTERS

790

CONNECTING BLOCK

XANTEC

IN / OUT

IN / OUT

781RG

Power Supply

790-00

Connecting Block

780-10

J-Box IR Receiver

REMOTE ROOM

MAIN ROOM

Shield

+12 VDC

IR OUT

GND

780-10

J-BOX RECEIVER

To 120 VAC
(unswitched)

781RG

Power Supply

REMOTE ROOM

MAIN ROOM

Hand Held

Remote

VCR

GND

IR OUT

+12V

780-10

J-Box

IR Receiver

(rear view)

3-Conductor
Inter-room Cable
(unshielded OK)

789-44

Connecting Block

283M

 

Blink-IR™

Mouse Emitter

AV 

Receiver

Satellite Receiver

283M

 

Blink-IR™

283M

Blink-IR™

12VDC

+12 VDC

GND

STATUS

IR IN

EMITTERS

789-44

CONNECTING BLOCK

®

IR

RCVR

Fig. 2

  A 780-10 Basic IR Repeater System

11-9-00

Reviews: