background image

4

+12 VDC

IR OUT

GND

780-10

J-BOX RECEIVER

OUT

V

IR

RCVR

PWR

G

S

795-20

Four Zone

Amplified

Connecting

Block

Satellite Receiver

VCR

MAIN ROOM, EQUIPMENT CABINET, ETC.

Emitter

291-10

Hidden Link™

IR Receiver

GND

+12V

ZONE 2

780-10

J-Box

IR Receiver

3-Wire
Cable

GND

+12V

480-00

Dinky Link™

IR Receiver

Red
Stripe

Smart
Pad™

GND

IR OUT

+12V

ZONE 3

CD Changer

Laser Disc

ZONE 1

AV Receiver Zone  1

490-00 

Series

Micro Link™

IR Receivers

ZONE 4

3-Wire
Cable

IR OUT

GND

+12V

Red
Stripe

To 120 V AC
(unswitched)

782-00

Power Supply

Emitter

Emitter

Emitter

AV Receiver Zone  2

AV Receiver Zone  3

COMMON

SOURCES

ZONE

RECEIVERS

3-Conductor Cable
(unshielded OK)

AV Receiver Zone  4

590-00

Programmable Controller
(back view)

786-00

Power Supply

To Zone 4

Emitter

120 V AC

(unswitched)

To Zone 3

Emitter

To Zone 2

Emitter

To Zone 1

Emitter

1

12VDC

12VDC

1 2 3 4

BANK

RES DEL SEQ PGM

+

2

3

4

5

6

7

8

9 10 11

14 15 16

O G

+

12 13

AC

Power

Strip

786-00

Unregulated

Power Supplies
plugged into an

AC outlet on

each Zone

Receiver

+

White
striped
side

680-10

Remote AC
Switcher

599-00

Pulsed

Switching

Module

AC for

"Power Line Switchable"

Common Sources

Zone 1 AC

Zone 2 AC

Zone 3 AC

Zone 4 AC

RESET

120 V

A

C

15A

 MAX

OUTLET 4

5A
 MAX

OUTLET 5

5A
 MAX

OUTLET 6

5A
 MAX

OUTLET 1

5A
 MAX

OUTLET 2

5A
 MAX

OUTLET 3

5A
 MAX

IR

INPUT

CONFIRM

T

O

T

A

L

 LOAD LIMITED 

T

O

 15A

Cassette DecK

To 120 V AC

(Unswitched)

7 Foot Quick
Connect Cable

CB12

Connecting
Block

Do not use
these jacks

X  X

+

+

+

Zone 1
Emitter

Zone 2
Emitter

Zone 3
Emitter

Zone 4
Emitter

TEMPORAR

Y

 POWER 

T

A

P

CAUTION: 

T

O

 REDUCE 

THE RISK OF ELECTRIC SHOCK

USE INDOORS IN 

A

 DR

Y

 LOCA

TION.

680-10

REMOTE AC SWITCHER

IN+

IN–

GND

+12V

OFF

ON

GND

+12V

599-00

PULSED

SWITCHING

MODULE

283M 

Blink-IR™

Mouse Emitters

IR OUT

IR OUT

COMMON

ZONE

795-20

 

FOUR ZONE AMPLIFIED CONNECTING BLOCK

A

B

A

B

A

B

A

B

+12V

ZONE 1 ZONE 2 ZONE 3

ZONE 4

IR ZONE

ZONE 4

ZONE 3

ZONE 2

ZONE 1

+12 IN G +12 IN G +12 IN G +12 IN G

POWER

10 9 8 7 6 5 4 3 2 1

Fig. 3

  A typical application of the 680-10 for AC switching in a 4-zone system.

6. The common source components that can remember their ON condition when their power cords are

unplugged, are all powered from the #6 outlet on the 680-10.  Those that cannot, such as the VCR and
the Satellite Receiver shown in Fig. 3, must be plugged  into unswitched outlets and receive their IR
power commands from the 590 through the 795 and the common emitters.

7. The common sources are therefore switched ON when the first AV receiver is turned ON, and will

remain on until the last AV receiver is turned OFF.

8. Finally, ON and OFF IR commands from the RC68+, for outlets #1 through #4, are "taught" into a

learning remote, such as a Xantech URC-1, and into the Xantech Smart Pad, along with all other
desired system commands, for total system operation.

9. To embellish the system further, you could add the GP-ON and GP-OFF commands from the RC68+

programmer to the keypads or the URC-1 remotes so that all zones may be turned ON or OFF from
any zone location.

See the 795-20 Installation Instructions for additional information regarding zoned systems

MOUNTING

The 680-10 has four attached rubber feet for stand-alone mounting.  Underwriters Laboratories defines the
680-10 to be a moveable device and therefore it is not to be fastened down permanently to any surface.  It
may however, be placed in any orientation to accommodate the installation.

680-10

12-20-00

Rev.C

Reviews: