4. If you have products in the same IR system that have different IR carrier frequencies, you will have

to adjust the 291-80 to a midway position.  For example, some products may operate at 38 kHz and
others at 56 kHz.  In this case, set the adjustment to approximately 47 kHz, a midway position just to
the right of the 48 kHz marking in Fig. 2.

NOTE:  Some products are more tolerant of compromised frequency settings than others. You may
have to "fine tune" the adjustment to "favor" the least tolerant component for the best performance of
all units in the system.

Connecting IR Receivers From Other Rooms

The CB12 Connecting Block, supplied with the 291-80, has a three terminal input strip for connection of
external infrared receivers should you wish to control your equipment from other rooms.

• The terminals are marked V G S.  (V= +12V, G=Ground and S=IR Signal).

• Make connections as shown in Fig. 3.  Run a 3-conductor cable from each remote room to the VGS

terminals on the CB12.

(Use 24 gauge solid or stranded wire up to 200', 22 gauge up to 600', 20 gauge up to 2000' and 18 gauge
up to 5000' (unshielded OK).

• When you use a 291-10 or a 291-80 IR Receiver in a remote room, 

do not plug in a power supply or use

the "OUT" jack on that par-
ticular CB12, as shown in
ROOM 3 of Fig. 3.

• You may use more IR re-

ceivers, in additional rooms,
connected in the same man-
ner. When connecting more
than ten 291-80's, use the
higher current power sup-
ply, Model 782-00.

291-80 Cable Connections

The 291-80 may also be used
where the 7-foot cable is not
long enough.  Simply cut off
the mini plug, strip the leads
and splice them to a 3-con-
ductor extension cable using
a terminal block or other
means.  Then connect the extension cable to the 3-terminal block on the CB12.

Refer to Fig. 4 and the table below to identify the leads for correct connections.

Fig. 3

  Connecting IR Receivers From Other Rooms

7-Foot 3-

Conductor
Cable with

Quick Connect

Mini Plug

291-80

 IR Receiver

To 120 V AC

(Unswitched)

781RG

Power Supply

Hand Held

Remote

VCR

3-Conductor

Room-to-Room

Cable

(unshielded OK)

Equipment

Mounted Behind

Closed Doors

CB12

 Connecting Block

780-10

J-Box

IR Receiver

OUT

VGS

IR

RCVR

PWR

GND

OUT

+12V

+12V

OUTPUT

GND

780-10

J-BO

X

 RECEIVER

XANTECH CORPORA

TION

SYLMAR, CA

  91342

CB12

Connecting

Block

OUT

V G S

IR

RCVR

PWR

291-10

 IR Receiver

(See Text)

X    X

Model 286M

 Dual Blink IR™

Mouse Emitter

(Not  Included)

Satellite Receiver

ROOM 2

ROOM 3

ROOM 1

Table  

Lead Identifications

3-Terminal Block
(not included)

+12V

GND

SIG

WHITE

RED

BLACK

3-Conductor
Extension
Cable

7 Foot 3-Conductor Cable
with Mini Plug Removed

291-80

CB12

OUT

VGS

IR

RCVR

PWR

CABLE LEADS

CIRCUIT ITEM

BLACK

WHITE

RED

GROUND

SIGNAL

+ 12 V

PLUG

RING

TIP

SLEEVE

Fig. 4

  Direct Wire Connections

Tip

Ring

Sleeve

Insulators

Stereo Mini Plug

291-80