anCIllarY ParTS and SuPPlIeS

Your equipment installer will be carrying a CCD dot meter to 
calibrate the system during installation. However, we strongly 
recommend that you have a CCD dot meter on hand if you 
ever need to recalibrate the system. Xanté sells a dot meter, 
but meters by other leading manufacturers should work as well. 
Note the difference between a densitometer (including “plate 
densitometers”) and a dot meter. Densitometers measure dot 
area by shining a light on a region of the media and measuring 
how much light is reflected. Dot area meters use a CCD array 
(as is found in digital cameras) attached to microscope optics to 
measure the size of halftone spots. While both types of devices 
can be very accurate, CCD dot meters provide better results in 
practice because calibration of the meter is much more simple.

Please have a box of appropriate plate material for each size of 
press for which you’re planning to produce plates. If you’re using 
Xanté plate material, the following sizes are stocked as standard 
items, and other sizes can be special-ordered:
Harmony 8 mil Violet Metal Plates

• 

10" x 15" (254 x 381 mm ) 

• 

11" x 18" (279 x 457 mm) 

• 

11.25" x 18.5" (286 x 470 mm) 

• 

12.0625" x 17.375" (306 x 441 mm) 

• 

13" x 19.15625" (330 x 487 mm) 

• 

13" x 19.375" (330 x 492 mm) 

• 

13.1875" x 19.09375" (335 x 485 mm) 

• 

13.375" x 19.875" (340 x 505 mm) 

• 

15.75" x 18.5" (400 x 470 mm) 

• 

15.75" x 20.0625" (400 x 510 mm) 

• 

15.75" x 20.125" (400 x 511 mm) 

• 

16" x 17.5" (406 x 445 mm) 

• 

18.0625" x 20.687" (459 x 525 mm) 

• 

19.6875" x 23" (500 x 584 mm) 

• 

19.875" x 22.75" (505 x 578 mm) 

• 

20.75" x 25.625" (527 x 676 mm) 

• 

21.6875" x 26.375" (550 x 670 mm) 

• 

22.5" x 28.5" (571.5 x 724 mm) 

• 

24.25" x 28.5" (616 x 724 mm)

Be sure to have the appropriate chemistry on hand for the plate 
material you have selected:

• 

Harmony Violet CTP Developer: Please have 5.2 gallons 

  (20 liters) of the developer on hand.

• 

Harmony Violet CTP Replenisher: Most plate materials 

  require a replenisher, which maintains the pH of the developer 
  chemistry. If needed, please have 5.2 gallons (20 liters) on hand.

• 

Harmony Violet CTP Gum: Please have 2.6 gallons/10 liters 

  of gum concentrate.

The best tool for monitoring plate processor chemistry is a 
pH meter, which is shipped with the P24 processor. It is also 
important to maintain proper temperature. To measure both, we 
recommend the Hanna Instruments pHep4 (HI 98127), along 
with the 7/10pH calibration kit (HI 770710P) to maintain calibra-
tion. For more information, visit the Hanna Instruments website at 

http://www.hannainst.com/products/prodline/tester.cfm. 
They can be ordered from Professional Equipment at 
http://www.professionalequipment.com.

To calibrate the temperature of the processor, we recommend 
non-reversible temperature labels. These labels can be attached 
to plates (5 per plate), and will show the highest temperature 
which the plate reached, even after it has cooled down. Your 
installer will have enough for the installation, but they may come 
in handy later on for diagnostic purposes. They can be ordered 
from xante.com, omega.com and t-m-c.com. We recommend 
labels with a temperature range of 190-280 degrees Fahrenheit 
(90-135 degrees C), with 10 degree F resolution.

If any of the presses require plates to be punched, then you 
should have the appropriate punches on hand. Xanté sells plate 
punches for certain presses, and they are also typically avail-
able from the press manufacturer and third parties. The VM CTP 
system registers the image to the gripper edge and right edge 
of the plate. For best registration on press, the punch should 
also register to those edges. Centering punches can typically be 
modified to work that way, and your installer can assist you with 
making that change to your punch, if needed.

For evaluating dot size, quality, and exposure level, we recom-
mend a 30x magnifier or loupe. A plate exposure scale will also 
be necessary to set laser power — consult the plate manufac-
turer for the appropriate one for the material. Xanté plate material 
requires a Stouffer 21 step wedge (step 3 solid, step 5 ghost) or 
a UGRA wedge (step 2 solid, 4 ghost).

SYSTem delIverY

The components of your CTP system will arrive from several dif-
ferent locations, typically over the course of a few days. The VM 
CTP system and the VM CTP system stand are typically shipped 
by truck freight from Xanté in Hauppage, NY. The PlateRunner 
P24 processor with stand (3 crates total) is shipped by truck 
freight from Xanté in Mobile, AL. The RIP computer and scanner 
(if applicable) will ship from Xanté in Citrus Heights, CA. Other 
components ship from various locations. All components should 
be in place prior to the arrival of the installation crew, and Xanté 
tracks all shipments to ensure that they will arrive on time.

All crates should be moved to the area where the equipment 
will be installed. The following crates may require special con-
sideration with respect to doorway dimensions and movement. 
Please ensure that there is a way to get each of these crates 
from the truck to the installation area:

 

height 

depth 

width 

weight

VM CTP System 

33" (84cm)  28" (71cm)  52" (132cm)  334 lbs. (151kg)

VM CTP System Stand  31" (79cm)  38" (97cm)  53” (135cm)  285 lbs. (129kg)
P24 Processor 

39” (100cm)  32” (82cm)  63” (160cm)  450lbs (204kg)

CTP Site Preparation Guide  

page 3

Summary of Contents for PlateRunner P24 Processor

Page 1: ...ay damage the system Yellow Safelight Yellow Room All violet sensitive plate materials on the market at this time require special lighting conditions in order to avoid fogging undesired exposure It is necessary to control all the sources of light in the area around the platesetter and processor while plates are being handled both ambient light and direct light Ambient light can be controlled by us...

Page 2: ...aily may have a higher concentration of contaminants than water which is continually replaced during normal operation of the machine using a fresh water supply You will need to supply two 5 gallon 20 liter containers one for the developer waste and one for a gum recirculation container For both of these containers it is best if they have a small neck or are closed this limits evaporation and odor ...

Page 3: ...fm They can be ordered from Professional Equipment at http www professionalequipment com To calibrate the temperature of the processor we recommend non reversible temperature labels These labels can be attached to plates 5 per plate and will show the highest temperature which the plate reached even after it has cooled down Your installer will have enough for the installation but they may come in h...

Page 4: ... of lifting 100 lbs 45 kg to assemble the processor VM CTP System and optional stand Please unpack the VM CTP System and if applicable its stand and place the VM CTP System in the final position prior to the arrival of the installation crew Do not connect power to the VM CTP System We recommend using four people to lift the VM CTP System into position RIP and other components Please do not unpack ...

Page 5: ... CTP system and plate processor The front of the VM CTP system and entry rack of the processor are immediately adjacent The computer and VM CTP system can be connected by a 15 foot cable I have a cart or table to hold the computer I ordered the VM CTP system stand or I have a strong table for the VM CTP system to support 334 lbs 151kg and light safe storage for plates List presses and press sizes ...

Page 6: ...I have a box or more of plate material for each type of press I plan to use I have 5 2 gallons 20 liters of Harmony Violet CTP developer which are compatible with my plate material I have 5 2 gallons 20 liters of Harmony Violet CTP replenisher which are compatible with my plate material I have 2 6 gallon 10 liters of gum concentrate I have a pH meter and thermostat I have a supply of non reversibl...

Reviews: