Defender XD103- User Manual
10.
Adjusting spray pattern orientation
a.
The fan pattern can be adjusted from horizontal to vertical by adjusting the air cap.
b.
Slightly loosen the air cap retaining nut and rotate air cap to desired position.
c.
Retighten the air cap retaining nut.
11.
Plug atomizer into power source. Pull trigger and disinfectant will spray from the nozzle.
12.
Application distance and speed are important. Atomizer should be 4 feet or greater from the surface being
disinfected. Surfaces being sprayed should be completely dry within 5-10 minutes of spraying. Wiping wet
disinfectant off the surfaces should not be required. However, the surfaces should remain wet long enough (dwell
time) for the disinfectant to be effective, at least one minute. See disinfectant manufacturer’s recommendations
for dwell time for the specific disinfectant being applied.
a.
If surfaces remain wet longer than 5-10 minutes, increase movement speed of the atomizer to produce a
lighter coating.
b.
If surfaces are not fully wetted, slow down movement speed of the atomizer.
V Maintenance
1.
Cleaning
a.
Unplug unit from outlet.
b.
Separate atomizer from motor/blower assembly
c.
Remove disinfectant container from atomizer
d.
Remove any remaining disinfectant from disinfectant container and dispose of as per disinfectant
manufacturer’s recommendations.
e.
Add approximately 200 mL of water to disinfectant container. A few drops of liquid soap or dishwashing
liquid can also be added.
f.
Reassemble container to atomizer, then assemble atomizer with motor/blower.
g.
Swish water in container to wet the interior of the container (and to mix in soap, if used).
h.
Plug unit into outlet.
i.
Turn on atomizer and run until container is empty.
j.
Repeat steps above one additional time with water only.