The datalogger is equipped with an intelligent energy management system
that lowers power consumption to about 1 mA (at 12 V supply voltage) in
sleep mode.
The device goes into sleep mode via the following actions or under the
following conditions:
▪
Pressing and holding the power button
(K)
for at least 2 seconds.
Current recording stops automatically.
▪
If no data reach the log interfaces and no connection to the
X
ORAYA
Suite is established for 10 minutes, the datalogger shuts down
automatically. This behavior is configured using the main setting
Automatically Switch Off
. (
➔
Users can wake up the datalogger from sleep mode as follows:
▪
Pressing the power button
(K)
▪
Switching the power supply off and on
▪
Signal change from 0 V to +12 V at the trigger or wake input
(L)
▪
Pressing the trigger/wake button
(J)
▪
Activity on a wakeable log interface
4.6
Connecting the datalogger to the PC
This section describes how to connect the datalogger to the PC. To do so,
you will need a standard network cable.
Proceed as follows to connect:
Connect the network cable to a switch.
or
Connect the network cable directly to your PC.
Connect the network cable to one of the LAN host ports
(E)
on the
datalogger. (
➔
The datalogger is fully connected.