- 11 -
No/insufficient airflow
•
Ensure there are no blockages in the
nozzle or hot air gun shaft
•
Adjust the air flow knob to a higher
setting
•
Contact the manufacturer.
Noisy unit
•
Ensure the unit is on a flat, level
surface
•
Ensure all of the screws and brackets
are secure
•
Contact the manufacturer
Excessive vibration coming
from the unit
•
Ensure the screws from the bottom of
the unit have been removed
•
Ensure the unit is on a flat level surface
•
Contact the manufacturer
Replacing Heating Elements
Soldering Iron
1. Turn off the unit and unplug it from the power source.
2. Allow the unit to reach room temperature before proceeding.
3. Disconnect the soldering iron from the unit.
4. Loosen the nut on the metallic shaft.
5. Slide the metallic shaft off of the soldering iron.
6. Remove the soldering iron tip and inner shaft.
7. Unscrew the plastic nut from the top of the soldering iron.
8. Push the cord through the bottom of the soldering iron while pulling
the heating element out of the top of the soldering iron, exposing
the circuit board
9. Unsolder the existing heating element, taking note of the wire color
and location.
10. Remove the heating element.
11. Replace the heating element.
12. Solder the new element leads in the correct location.
13. Pull the cord out the bottom of the soldering iron while pushing the
new heating element into the top, aligning it with the notches.
14. Replace the plastic nut to the top of the soldering iron and tighten.
15. Replace the inner, small metallic shaft.
Summary of Contents for 8080
Page 1: ...X TRONIC USA X Tronic Model 8080 Instructions...
Page 2: ......