X-TREME Monitor Series User Manual Download Page 5

User’s manual

6. XT-NET

All the monitors can be linked together and connected to a PC for re-
mote management via the 

XT-NET

 network. In general terms, the XT-

NET network makes it possible to simultaneously connect up to “N” 
X-Treme active arrays (XTLSA/A, XTMISI/A, XTMLA/A) and monitors 
(XTMON12/A, XTMON15/A) as well as “M” XTDP processors via a PC, 
and to manage them all at the same time using a unique software ap-
plication for running X-Treme electronics: called 

Network Controller

It displays at once an individual control panel for each of the external 
processors  and  active  loudspeaker  systems  connected  to  the  net-
work. The link is made by using an RJ145 cable.

It  is  important  to  take  the  following  features/functions  into  account 
to safeguard recognition of the device and thus the link between the 
panel and device:
•  The user can assign a 

name

 to each device: the name remains as-

signed also after shutdown. This is done via the control panel on 
each individual device.

•  The devices are listed under their assigned names in alphabetical 

order.  If  they  have  no  assigned  name,  they  are  displayed  at  ran-
dom.

•  The sequence does not depend on the order in the cascade con-

nection of the devices, as they are all seen “in parallel”. 

There is a 

Locate device

 function for finding devices managed by a panel. 

If this function is operated from a single panel, a LED will flash (speakers 
on) or a description will appear on the display (XTDP processors).
Based on these features, there are 

two

 basic ways to correctly set a 

session for the XT-NET network: 
a) assign  a 

physical  label

  to  each  device  and  always  use  it  for  the 

same, clear purpose (e.g. central monitor, third speaker in an array, 
etc.). If a “software” name is assigned to each device that matches 
its  physical  label,  simply  connect  up  all  of  the  network  and  open 
all  the  panels  for  an  immediate  and  clear  vision  of  the  system  of 
names.

b) otherwise, if the various devices do not have a fixed role and a cor-

responding physical label (as with array modules that are swapped 
over from time to time), use the 

Locate device

 function to correctly 

assign the panels to the various devices, assigning temporary soft-
ware names. 

6.1 XT-NET management functions

The X-Treme self-powered monitors are designed with a basic sound 
consisting of 2 

internal presets

 that can be selected with the appropri-

ate 

switch 1

 on the back of the speaker. 

XT-NET input 
and link for
Cat. 5 cable 
with RJ145 
connector

SWITCH 2

SWITCH 1

5/