Page 1: ...1 REV 3 210 OPERATION MANUAL X TINGUISH X TREME AEROSOL FIRE SUPPRESSION TOOL ...

Page 2: ...sh X TREME 5 PREPARING FOR DEPLOYMENT 5 X Tinguish X TREME QUICK START GUIDE WITH GRAPHICS 6 DEPLOYING THE X TINGUISH X TREME 7 AFTER USING THE X TINGUISH X TREME 8 IN THE AFFECTED AREA 8 FIREFIGHTER FIRST RESPONDER NOTE 8 WARNINGS AND GUIDELINES 9 ENVIRONMENTAL 9 CLEAN UP AFTER DEPLOYMENT 9 FIRST AID PROCEDURES 10 EYE CONTACT 10 SKIN CONTACT 10 INGESTION 10 INHALATION 10 LIMITED WARRANTY 11 CONTA...

Page 3: ...ts a giant advance in fire suppression technology from water or other chemical based methods The X TINGUISH X TREME is a small portable unit that contains potassium based chemical components It is designed to be a first use method to combat class A B C and K fires When the device is deployed at the scene of a fire the X TINGUISH X TREME releases a cloud of aerosol containing the potassium componen...

Page 4: ...he fire s chemical reaction without affecting oxygen levels When used in accordance with these instructions deployment of the X TINGUISH X TREME poses no risk to occupants and first responders and will effectively minimize any of the fires collateral and environmental damage The device inhibits the fire from obtaining the oxygen radicals it needs to continue burning and spreading further Once acti...

Page 5: ... should not be deployed Should the Igniter pin and ring become detached accidentally from the unit immediately throw the unit away from yourself and any person in the vicinity At this point the 8 second countdown until ignition has begun and CANNOT be reset The unit will deploy its aerosol after the 8 second countdown STORAGE Keep the X TINGUISH X TREME in its original case whenever possible and s...

Page 6: ... the R Pin firmly grasp the Igniter Pin 1 and pull it straight out of the unit Once the Igniter pin has been pulled the 8 second count down until deployment will start and this action cannot be stopped once initiated You must deploy the unit immediately after pulling the pin Picture 2 OVERHAUL AND LOOK FOR HOTSPOTS AS USUAL 5 1 2 3 4 Call 855 377 2100 or email info flameguardusa com with any quest...

Page 7: ...INITY Once the Igniter pin has been pulled the device is now activated and will begin dispersing the aerosol in 8 seconds After the igniter pin has been pulled DO NOT ATTEMPT to prevent the activa tion of the device Never attempt to retrieve a device that has been activated or to re install the yellow security pin Make sure that the person deploying the device can accurately throw the unit toward ...

Page 8: ...l While the X Tinguish X TREME is a safe and effective method of fire suppression it is im portant to always adhere the guidelines when using the X Tinguish X TREME Firefighters or other fire prevention officials should use the X Tinguish X TREME devices only in accordance with their departments local rules or guidelines This Operation Manual is not intended to replace or supersede any fire depart...

Page 9: ...cipality GLOBAL WARMING IMPACT The X Tinguish X TREME does not pose any global warming threats It measures zero on both the Ozone Depletion Potential and Global Warming Potential scales CLEAN UP FOLLOWING DEPLOYMENT THE X Tinguish X TREME UNIT The used X Tinguish X TREME unit can be disposed of according to the normal disposal procedures for other fire related materials THE AEROSOL RESIDUE If the ...

Page 10: ...osol can cause mild skin irritation including slight reddening of the skin Wash affected area with soap or mild detergent and water until no evidence of chemical remain If any conditions continue consult a physician INGESTION If somehow the metal casing is opened and the product inside is ingested the fol lowing is recommended Remove by gastric lavage or emesis Maintain blood pressure and airway G...

Page 11: ... all other warranties or remedies express implied or statutory and all other obligations or liabilities of Company with respect to the Products including but not limited to warranties of merchantability or fitness for a purpose DisclaimerofResponsibility NeithertheSuppliernoritsdirectors officers employees oragentsshall beheld liablefor anyimproperorincorrectuseoftheProductsandassumenoresponsibili...

Page 12: ...12 Sales help sales flameguardusa com Technical help info flameguardusa com URL https www flameguardusa com Toll Free 855 377 2100 Local 815 219 4074 Fax 847 387 3824 CONTACT US ...