X-Rite PANTONE Judge QC Operation Manual Download Page 2

Judge QC 

P/N 

JQCUSMA-ENG Rev. A

 

 

Consult this documentation in all cases where the Attention symbol 

 appears. This symbol is used to 

inform you of any potential HAZARD or actions that may require your attention. 

CE Declaration 

Hereby, X-Rite PANTONE®® declares that this Judge QC is in compliance with the essential requirements and 
other relevant provisions of Directive(s) EMC 2004/108/EC, LVD 2006/95/EC, and RoHS 2011/65/EU. 
 

Federal Communications Commission Notice 

NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, 
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against 
harmful interference when the equipment is operated in a commercial environment. This equipment 
generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the 
instruction manual, may cause harmful interference to radio communications. Operation of this equipment 
in a residential area is likely to cause harmful interference in which case the user will be required to correct 
the interference at his own expense. 
 

Industry Canada Compliance Statement 

This Class A digital apparatus complies with Canadian ICES-003. 
Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada. 

 

 Safety Information 

 

 

IF THE EQUIPMENT IS USED IN A MANNER NOT SPECIFIED BY X-RITE PANTONE®, THE 
PROTECTION PROVIDED BY THE EQUIPMENT MAY BE IMPAIRED. 

 

PLEASE READ AND FOLLOW INSTRUCTIONS

: Read and follow all instructions before you attempt 

to assemble, install or operate the unit.  

 

CAUTION! THIS UNIT MUST BE EARTHED. DO NOT

 connect to an ungrounded outlet. 

DO NOT 

use 

with 2-wire extension cords or adaptors. 

 

OBEY WARNINGS:

 Please comply with all warnings and safeguards that we provide in this manual. 

They have been written to keep you and your unit safe. If the unit is used in a manner not 
specified in this manual, the protection provided by the unit may be impaired.  

 

CANOPY WEIGHS APPROXIMATELY 15 KG. ASSEMBLED UNIT WEIGHS APPROXIMATELY 27 KG.

 

Take care when lifting and obey manual handling safety procedures.

 

 

TAKE CARE NOT TO TRAP FINGERS OR HANDS WHEN POSITIONING THE CANOPY ON TOP OF THE 
BACK, SIDES AND BASE DURING ASSEMBLY. 

Place hands under the front edge and on the outside 

of the canopy only.

 

 

CHECK VOLTAGE SETTING PRIOR TO PLUGING IN THE UNIT. 

Applying the incorrect voltage may 

cause the fuses to blow. Contact your local X-Rite representative for replacement fuses and follow 
the fuse replacement procedure in this manual. 

 

ALWAYS UNPLUG THE UNIT BEFORE CHANGING THE VOLTAGE SELECTOR OR FUSE. 

 

NEVER BLOCK ACCESS TO THE MAINS INLET AND POWER SWITCH. 

The mains inlet and power 

switch are located at the rear of the unit.  

 

DO NOT BLOCK VENTS:

 The vents allow air to circulate between the canopy interior and the 

ambient air. Blocking the vents will cause hot air to build up within the canopy which may result in 
inaccurate lighting conditions, damage to the equipment, and possible personal injury. 

 

USE ONLY A PROPER POWER SOURCE:

 Use the proper power source for this unit. Consult the 

power label on the back of the unit for this information. Operation with a power source not 
specified on the power label may result in inaccurate lighting conditions, damage to the 
equipment, and possible personal injury.  

Summary of Contents for PANTONE Judge QC

Page 1: ...EN Operation Manual...

Page 2: ...e install or operate the unit CAUTION THIS UNIT MUST BE EARTHED DO NOT connect to an ungrounded outlet DO NOT use with 2 wire extension cords or adaptors OBEY WARNINGS Please comply with all warnings...

Page 3: ...he unit Disposal Instructions for disposal Please dispose of Waste Electrical and Electronic Equipment WEEE at designated collection points for the recycling of such equipment Proprietary Notice The c...

Page 4: ...and any other charges for products returned to any other locations Proof of purchase in the form of a bill of sale or receipted invoice which is evidence that the unit is within the Warranty period m...

Page 5: ...es Five light sources Daylight CIE D65 6500 K or CIE D50 5000 K Store 1 or Daylight Halophosphor Cool White CWF 4100 K or CIE D50 5000 K in Dual Daylight Models Store 2 Triphosphor 840 4000 K or 835 3...

Page 6: ...amage to the equipment and possible personal injury Make certain that the unit is placed on a stable vibration free surface that will support the weight of the unit Assembled weight 27 Kg When choosin...

Page 7: ...container to the general area that the cabinet is to be used Be sure to allow sufficient room for assembly Carefully examine shipping containers for contents before discarding Please check the conten...

Page 8: ...steps 1 and 2 for the Right Side 3 Step 4 Slide the Back Panel 4 down inside the folds on the Left Side 2 and Right Side 3 until it rests on the Base Panel 1 Step 5 Secure the Back Panel 4 to the Bas...

Page 9: ...Judge QC 9 P N JQCUSMA ENG Rev A Step 6 Place the Canopy 5 on to the assembled Back Sides and Base Step 7 Secure the Canopy 5 in place using four Screws a a 4 5 a a a a 5...

Page 10: ...ified by X Rite PANTONE the protection provided by the equipment may be impaired CAUTION THIS UNIT MUST BE EARTHED DO NOT connect to an ungrounded outlet DO NOT use with 2 wire extension cords or adap...

Page 11: ...D IS INCORRECT proceed to Changing the Voltage Selection Unit below Changing the Voltage Selection Unit ALWAYS UNPLUG THE UNIT BEFORE CHANGING THE VOLTAGE SELECTOR OR FUSE 1 To remove the Fuse Drawer...

Page 12: ...connect the power cord to the unit and apply power If the unit shows signs that the fuses may have blown again contact your X Rite PANTONE Service Representative Selecting a Light Source NOTE Refer to...

Page 13: ...s interfere with lamp performance 1 When the Lamp Status indicator is flashing RED all of the lamps within the cabinet should be replaced 2 To remove the fluorescent lamps rotate the bulb until the pi...

Page 14: ...uminate when this has registered b Then push and hold the second button from the left for 3 seconds c Switch the power off unit The lamp status indicator is reset and will only resume counting from wh...

Page 15: ...WF UV LS5DDCWF Full Lamp replacement kit for Judge QC and Pantone 5 Light Booth 2 x D50 D65 A 1x CWF UV L24D50 D50 Individual 24 Lamp For JudgeII JudgeQC and Pantone 3 5 two required per booth L24D65...

Page 16: ...41 Fax 813 5436 1616 Asia Pacific Headquarters X Rite Asia Pacific Limited Suite 2801 28 th Floor AXA Tower Landmark East 100 How Ming Street Kwun Tong Kowloon Hong Kong Phone 852 2568 6283 Fax 852 28...

Reviews: