6.2 APU START
In the interests of ease of use, both start procedure types are complete with all notations. These
steps result in complete power on settings - they are not 1:1 with the simulation checklists that include
even more detail.
1. Fuel DC pump and AC pumps 1 & 2: AUTO
2. HYD SYS 1, 2, PUMPS: AUTO
3. Battery 1 and 2: ON
4. TRU 1 & 2: AUTO
5. TRU ESS: AUTO
Steps 4 & 5 are essential if you want the autopilot to follow your flight plan, or to work at all.
6. APU GEN: ON
7. AC POWER: ON
8. TRU 1 & 2: AUTO
9. TRU ESS: AUTO