4.
Communication Configuration
The following settings will allow for proper communication with the unit to ensure access. Configure these settings before
attempting to communicate with the unit.
Communicating via RS-232
Baud Rate: 9600
Parity:
None
Data Bit:
8
Stop Bit:
1
Communicating via IP
Enabling Telnet Client in the PC
By default, the Telnet client is disabled within Windows. Follow the steps below to enable the Telnet client.
1.
Navigate to: Control Panel > Programs.
2.
In Programs and Features area box, click Turn Windows features on or off.
3.
In the Windows Features dialog box, select the Telnet Client check box.
Logging into the Switcher
The switcher is accessed via a command-line (CMD). The following steps are specific to Windows 7, actual path to the command
line may vary based on operating system.
1.
Navigate to: Start > Run.
2.