17
Spray Bar
The Spray Bar is controlled by the spray bar valve. Open
the main tank valve and close the bypass valve.
Start the engine and increase to full throttle. Open the spray
bar valve. Use the pickup/tractor speed to control the rate
that water is applied. The amount of water flowing through
the spray bar can be controlled by partially closing the
spray bar valve or slightly opening the bypass valve. Do
not close the main tank valve. Pump damage can result.
The spray bar covers a maximum swath of 25’. Common
uses include controlling dust on roads or pre-wetting areas
to help prevent spread of fire.
Operation -- Fire Control
In order to fill the tank with the transfer pump close the main
tank valve and attach the fill hose to the suction manifold
(500/800 gal.) or quick-fill coupler (1,025 gal.). Open the
bypass valve on the discharge manifold (500/800 gal.) or
bypass valve (1,025 gal.). Set the end of the fill hose in the
pond, tank or other water source with the suction screen
coupled to the end of the hose. Be sure that the suction
hose bibb is closed. A partially open bibb will let air into
the suction manifold, causing cavitation in the pump and
a lack of pressure.
Figure B30
Filling From Open Water (500/800 Gal.)
Figure B31
Filling From Open Water (1,025 Gal.)
Figure B32
Spray Bar Valve/Bypass Valve Setting
Figure B33
Spray Bar Nozzles (500 Gal.)
< Closed Main Tank Valve
Strainer >
Open Bypass Valve >
Closed Bypass Valve >
Open Spray Bar Valve >
Strainer >
< Closed Main Tank Valve
< Open Bypass Valve
Open Quick
Fill Valve >
Open Main Tank Valve >
Spray Bar Nozzles