SETUP
The motor has several options for connecting the core and
casing assembly to the motor housing For all available
connections, see
Connecting the Vibrating Casing
(Quick-Disconnect Connections)
OTEE:
N
The casing must be fitted with a
quick-disconnect end
1 Make sure the locking lever on the quick-disconnect
connector on the motor is in the up position See
Locking Lever
Figure 2: Quick-disconnect fitting
2 Locate the core and casing
3 Identify the side of the casing that has the
connection arrow
4 Position the casing with the arrow face to the left as
viewed from the vibrator head end This side should face
to the left when the casing is held directly behind the
quick-disconnect See
Figure 3: Casing arrow location
5 Align the end of the core with the driver inside the
quick-disconnect fitting on the motor
6 Align the arrows on the casing end with the unlock icon
on the quick-disconnect connector The unlock and lock
positions are shown by the unlock and lock icons (see
) on the side of the quick-disconnect fitting
See
UnLocked
Locked
Figure 4: Unlock/Lock icons
Shaft
Figure 5: Core/Casing alignment
7 Insert the casing into the core
8 Line up the shaft and driver so the shaft slides into
the driver
9 Rotate the casing until the arrow lines up with the lock
icon on the quick-disconnect connector
10 Push down on the locking lever to clamp the
casing into the quick-disconnect connector
The locking lever bottoms out on the side of the
quick-disconnect connector
Setup
Page 8
February 2020
VBR-UM-02653-EN-05