Wybron Net IT User Manual Download Page 21

 

21 

Troubleshooting 

 
 

Problem  

 

Net-IT will not connect to my Art-Net or E1.31 network. 

 

Solution  

On the Net-IT display, read the IP address and subnet mask. 
Verify what the IP address and subnet mask is of your network. 
If they are different, then connect the Net-IT directly to a PC or MAC with an Ethernet 
crossover cable. Set the PC or MAC IP address and subnet to match the Net-IT. Open 
a web browser and enter the IP address of the Net-IT. Change the IP address and 
subnet mask to the desired values of your network and click on submit. Re-connect the 
Net-IT to your network. 
Make sure the router that you are using is on the right subnet. 
Check all Ethernet cables to the Net IT and router. 
Cycle power on the Net IT, Computer and router. 

 

Problem  

 

Net-IT is connected to my network but it is not sending out the DMX assigned to it. 

 

Solution  

Verify that everything is working correctly first for the above problem. 
For an Art-Net network, view the display on the Net-IT and verify that the Art-Net 
parameters for subnet and universe are set correctly. If they are not then change them 
by accessing the Net-IT’s web page. 
For a E1.31 network, view the display on the Net-IT and verify that the universe 
numbers are set correctly. If they are not then change them by going to the Net-IT’s web 
page. 
Verify that the sender of Art-Net or E1.31 is configured to the correct subnet and 
universe. 
 

Problem  

 

Net IT will not connect to the Infogate software on my PC or MAC (Net-IT name does 
not show on top right corner or it shows in yellow). 
 

Solution 

This is almost always caused by the computer and Net-IT being on different subnets.  
Read the Net-IT display to get the IP address and subnet mask. 
Verify that the host computer and router are on the same subnet as the Net-IT. 
Cycle power on the Net IT, Computer and router. 
 

 

Summary of Contents for Net IT

Page 1: ...Net IT Net IT PS600 User Manual ...

Page 2: ... Notice 3 Introduction 7 Quick Start Guide 8 Net IT Connection Diagram 12 Net IT PS 600 Connection Diagram 13 Front and Back Panels 14 Net IT Operation 16 Net IT PS 600 Head Feet Restrictions 18 InfoTrace RDM System Overview 20 Troubleshooting 21 Cables 23 Appendix A Definitions acronyms and abbreviations 24 User Manual Revision History 26 ...

Page 3: ...en Use in a dry location only The Net IT is to be used in an indoor environment only and is not intended for residential use Replace only with same type and rating of fuse Protection against electric shock is assured only if the mains connected power supply cord set is connected to a properly earthed grounding type receptacle For questions contact Wybron at 1 800 624 0146 Product Modification Warn...

Page 4: ...re le risque de feu remplacer seulement avec le même type et le même classement de fusible La Protection contre la décharge électrique est seulement assurée si la série de corde connectée principale est connectée à un convenablement terre de type Un appareil débranchant doit être localisé à côté de l unité ou si la corde de courant alternatif est utilisée comme le principal débranche l appareil S ...

Page 5: ...a el riesgo del fuego reemplaza sólo con mismo tipo y calificación de fusible La Protección contra calambre se asegura sólo si el conjunto conectado principal de cuerda es conectado a un apropiadamente earthed que muele receptáculo de tipo Una toda asta desconecta dispositivo se debe localizar adyacente a la unidad o si la cuerda de C A se utiliza como el principal desconecta dispositivo asegure q...

Page 6: ...tzten Schutz gegen Risiko des Feuers ersetzt nur mit gleichem Typ und Bewertung der Sicherung Schutz gegen Elektroschock ist nur gesichert wenn die Hauptleitungen Schnursatz verbunden haben ist an eine ordentlich earthed Erdung von Behälter angeschlossen Eine alle Stange schaltet Vorrichtung muss sich befunden werden neben der Einheit ab oder Wenn die AC Schnur benutzt ist während die Hauptleitung...

Page 7: ...contains all of the RDM device control and feedback functionality found in the Infogate Gateway The Infogate GUI application will make a connection over the same Ethernet connection that is used to receive streaming DMX Please consult the Infogate Users manual for details on its use This product also has six 4 pin powered output ports for Wybron devices These ports send 24 volts DC and the DMX sig...

Page 8: ... Net IT IP address is 10 1 2 3 and the subnet mask is 255 0 0 0 then set your computer to IP 10 0 0 2 and subnet 255 0 0 0 4 Open a web browser and enter the IP address of the Net IT to get to its web page If you can see the web page then you have the computer and Net IT correctly configured to the same subnet 5 If you want more detailed instructions than are in this Quick Start guide then click o...

Page 9: ...es or consoles Any Art Net source on the network will automatically find the Net IT If you configured the Net IT to DHCP then it will stop 11 Connect a DMX 5 pin cable to output A of the Net IT and run to your fixtures 12 Install the supplied Infogate software onto a PC or Mac connected to your network and launch it If the network is properly configured the Infogate GUI will connect to the Net IT ...

Page 10: ...10 Sample Web page for Art Net configuration ...

Page 11: ...11 Sample Web page for E1 31 configuration ...

Page 12: ...12 Net IT Connection Diagram Infogate Software Net IT Ethernet Lighting console Wybron Powered 4 pin 5 pin DMX Universe A Universe B Wybron PS 600 ...

Page 13: ...13 Net IT PS 600 Connection Diagram Infogate Software Net IT PS 600 Ethernet Lighting console Wybron Powered 4 pin Universe A 5 pin DMX Universe A Universe B ...

Page 14: ...dicate the following One green LED labeled LAN flashes if the Net IT is connected to a network One green LED labeled 100Mbps that stays on if lit the link speed is 100Mbps Two blue LEDs stay on if DMX is being transmitted on port A or B happens during and after Infogate Discovery command They flash if DMX is being received from the network Two blue LEDs flash when RDM is being transmitted or recei...

Page 15: ... LCD Screen 2 Page button 3 RDM A LED 4 RDM B LED 5 Line Speed 100Mbps 6 DMX A output 7 DMX B output 8 Ethernet connector 9 Power LED 10 DMX A LED 11 DMX B LED 12 Fuse 250V 1 0A slo blow 1 2 5 3 4 6 7 8 10 9 11 13 12 ...

Page 16: ...n your network on the web page enter 0 0 0 0 for the IP address and click on Submit The Net IT will re boot and DHCP To get back to the web page read the new IP address off the display and enter it into your web browser Setting the DMX Network Protocol On the web page you may select the network protocol from a pulldown option then click on Submit If you had previously assigned DMX universes to the...

Page 17: ...x when it is ON or 2 x x x when it is OFF This is true only while the unit is still using the factory default IP address If a full manual IP address is entered then the Network switch has no effect until a factory reset is performed Reset Factory Defaults To reset the Net IT to factory defaults including IP address use a paperclip to hold down the rest button for ten seconds The display will show ...

Page 18: ... where you have multiple water sprinkler heads color changers If the hose cable is too long or you have too many sprinkler heads color changers the water pressure voltage will be too low HEAD FEET is defined as the sum of cable lengths from each device to a single power supply output Head Feet Example The length of cable from the Net IT PS 600 to 1st Coloram 100 2nd Coloram 120 3rd Coloram 140 360...

Page 19: ...ten 2560 2570 1500 32 NexeraLX CDM 2580 2600 1500 24 Forerunner 4 inch 4540 7140 1500 64 Coloram IT 4 7 5 84520 87110 1500 24 Coloram IT 10 810100 1000 16 CXI IT 4 7 5 84560 87200 1500 24 CXI IT 12 812210 500 8 Aquaram IT 7 5 87080 1000 20 Ecilpse IT I Shutter 1K 2K 89001 81010 89020 811020 1500 32 Ecilpse IT II Iris 1K 87230 87250 1500 24 Ecilpse IT II Iris 2 k 812010 812020 1500 24 ...

Page 20: ...re equipped with a series of sensors that can relay a wealth of information to InfoGate These sensors can detect everything from light voltage and current to fan speed and even gelstring frame color information So while RDM equipment will allow identification and remote addressing IT equipment can give more specific status information and warn of potential problems possibly averting failures in th...

Page 21: ...ut the DMX assigned to it Solution Verify that everything is working correctly first for the above problem For an Art Net network view the display on the Net IT and verify that the Art Net parameters for subnet and universe are set correctly If they are not then change them by accessing the Net IT s web page For a E1 31 network view the display on the Net IT and verify that the universe numbers ar...

Page 22: ...annot scroll through the page feature then the software has been corrupted call Wybron Tech support Recycle the power on the Net IT The user will need to re flash the Net IT software For questions concerning Net IT and any other Wybron products please contact Tech support at 719 548 9774 ...

Page 23: ...ssis to chassis of the equipment The twisted pair shield is connected at male XLR connector end only XLR Pin Wire Color Function Size 1 White Ground 14 AWG 2 Green Data 22 AWG 3 Red Data 22 AWG 4 Black 24VDC 14 AWG DMX512 Control Cable The DMX control cable from the lighting console to the power supply is a five conductor cable with 5 pin XLR connectors on each end The wiring pin out is specified ...

Page 24: ...l for everything on a lighting rig MAC Address Media Access Control Address This is a unique number that is hard coded into every Ethernet device The MAC address is set in a unit when it is manufactured and it should never change Net IT This is a product that receives or DMX512 over Ethernet and does a protocol translation to straight DMX512 RDM Remote Device Management Protocol RDM permits intell...

Page 25: ...or written authorization WYBRON INC shall not be responsible for any incidental general or consequential damages to property damages for loss of use time profits or income or any other charges The owner s obligations during the warranty period under this warranty are to notify WYBRON INC at WYBRON INC s address within one week of any suspected defect and return the goods prepaid to WYBRON INC at t...

Page 26: ...26 User Manual Revision History Date Author Description 4 1 2010 Paul Geisler Original release ...

Reviews: