Manual Dead time Selection
CAUTION:
Dead time must be monitored by an
oscilloscope in manual dead time mode to avoid
HS/LS overlap
Four operating modes are available for MDC901 operation, defined by MHS_sel and MLS_sel state,
described in the truth table in Table 1.
Table 1: Truth table for mode selection
mode
select
synch/async
buck/boost
sync buck
PWM=VinHS
sync boost
PWM=VinLS
transparent
VinLS &
VinHS
MHS_sel
0
0
1
1
MLS_sel
0
1
0
1
Figure 6: Synchronous buck mode example with placed jumpers
Figure 6 displays an example of the EVB configured for manual dead time in synchronous buck mode
(determined by the MHS_sel and MLS_sel state, as well as the jumpers on
disILD and DTselect according to Table 1).
TgapOn is the time between the LS falling and HS rising as shown here:
TgapOff is the reverse situation to TgapOn from HS off to LS switching on.
DTselect
+9ns
TgapOn2
+18ns
TgapOn3
+36ns
TgapOn4
ZVSin
+9ns
TgapOff2
+18ns
TgapOff3
+36ns
TgapOff4
VinLS
VinHS
disILD
MHS_sel
MLS_sel
PWM
Placed
jumpers
LS
HS
HS
LS
TgapOff=2.8ns + …
TgapOn=2.8ns + …