Start signal
Command | 0x40
Length
Status
Result
CS
0x02
0x5E
0x03 0x00
0x00
0x00 0x00
0x5F
See the previous example to stop the test again.
7.5.2.4. Example: Set TX power to -4 dBm
Set the TX power to -4dBm (0xFC in two’s complement notation):
Start
signal
Command
Length
Command
code
Channel /
Vendor option
Length /
Vendor
command
Payload
CS
0x02
0x1E
0x04
0x00
0x02
0xFC
0x02
0x03
0xE7
Response:
Start signal
Command | 0x40
Length
Status
Result
CS
0x02
0x5E
0x03 0x00
0x00
0x00 0x00
0x5F
7.5.2.5. Example: Set PHY to 2MBit mode
Set the phy to 2MBit mode:
Start
signal
Command
Length
Command
code
Channel /
Vendor option
Length /
Vendor
command
Payload
CS
0x02
0x1E
0x04
0x00
0x00
0x02
0x02
0x00
0x18
Response:
Start signal
Command | 0x40
Length
Status
Result
CS
0x02
0x5E
0x03 0x00
0x00
0x00 0x00
0x5F
Proteus-e reference manual version 0.3
© November 2021
www.we-online.com/wireless-connectivity
59