7.1. Scan for other modules in range
7.1.1. CMD_SCANSTART_REQ
This command starts the scan operation to find other Proteus-III in range. All found devices
that fit the Proteus-III specification (i.e. devices that support AMBER SPP service UUID) are
saved in an internal data base. Before outputting the data base content using the command
, the scan has to be stopped using
Format:
Start signal
Command
Length
CS
0x02
0x09
0x00 0x00
0x0B
Response (
Start signal
Command | 0x40
Length
Status
CS
0x02
0x49
0x01 0x00
1 Byte
1 Byte
Status:
0x00:
Request received, will start scan now
0x01:
Operation failed
0xFF:
Operation not permitted
7.1.2. CMD_SCANSTOP_REQ
This command stops the scan operation that was started using
. It stores
the detected Proteus-III
addresses in an internal database, which can be output
using the
Format:
Start signal
Command
Length
CS
0x02
0x0A
0x00 0x00
0x08
Response (
Start signal
Command | 0x40
Length
Status
CS
0x02
0x4A
0x01 0x00
1 Byte
1 Byte
Status:
0x00:
Request received, will stop scan now
0x01:
Operation failed
0xFF:
Operation not permitted
Proteus-III reference manual version 1.3
© August 2020
www.we-online.com/wireless-connectivity
64