14
Installation
The remote adjuster with integrated thermostat RC21 provides you with easy to use temperature controlled adjust-
ment of heating from within your living space.
Settings
The dial is used to parallel translate the heating curve. The
fl
ow temperature (still regarding the outdoor tempera-
ture) is raised or lowered respectively by your adjustement. When the dial is turned all the way down, the heating
circuit is switched off. Frost protection stays active to prevent damage.
Sensor
The RC21 contains a temperature sensor which is used by the controller.
If the settings in the controller permit it, the sensor is used to alter the
fl
ow temperature.
The switch changes the operation mode of the controller.
In
Timer mode
the temperature is controlled according to the set thermostat periods.
In
Continous day
mode the set periods are ignored and the temperature is controlled according to the day
time settings.
In
Continous night mode
the temperature is usually set to lowest. This setting is best suited for periods of
long absence like e.g. holidays.
Installation
Carefully remove the dial from the housing with a screwdriver.
Loosen the screw beneath. Remove the white part of the housing from the black socket.
The RC21 is connected via terminal block to the controller.
Remote adjuster (grey)
Room temperature sensor (green)
Sensor earth (white)
The RC21 is suited for low voltage only!
D.4. - RC 21 Room thermostat and remote adjuster
Caution
RC21 is an optional accessory and not included in the scope of supply by default.
The Latento System Controller is fully operational without the RC21.
Danger!