Adding Oil to the Pump
Warning: Always add oil with cylinders fully
retracted (extended if pull cylinders) or the
system will contain more oil than the reservoir
can hold.
- Remove vent/fill cap from reservoir,
- Only fill the oil to approx. 2.0-2.5 cm below the upper
edge of the oil container (depending on the size of the
container),
- Remove air from system if necessary. See 8.3. Recheck oil
level after removing air,
- Return vent/fill cap to proper position.
- Make sure no dirt gets into the oil reservoir or into the
pump, as this will cause malfunction.
- To extend pump life and improve performance, lubricate
the beam pin, cross pin and piston head regulary, using
roller bearing grease.
13. Transport
13.1
For transport, the lever and the bolting device has to be a
locking position. The lever can be used as a carrying handle.
14. Troubleshooting
Cylinder does
not advance,
advances
slowly, or
advances in
spurts
Oil level in pump
reservoir is low
Add oil according to the
Maintenance instructions
on 12.1
Drain valve open
Drain valve closed
Loose hydraulic
coupler
Check that all couplers are
fully tightened
Load is too heavy
Do not attempt to lift more
than rated tonnage
Air trapped in system
Remove air according to the
instructions on page 8.3
Cylinder plunger
binding
Check for damage to
cylinder; have cylinder
by a authorised dealer or
Weitner themselves
Cylinder
advances, but
does not hold
pressure
Leaking connection
Check that all connections
are tight and leak free
Leaking seals
Locate leak(s) and have
equipment serviced by
authorised dealer or
Weitner themselves
Internal leakage in
pump
Have pump serviced by
a authorised dealer or
Weitner themselves
Cylinder does
not retract,
retracts part
way, or
retracts more
slowly than
normal
Drain valve closed
Open drain valve
Cylinder does
not retract,
retracts part
way, or
retracts more
slowly than
normal
Pump reservoir is
over-filled
Drain oil level to full mark.
See 12.1 instructions for
adding oil
Loose hydraulic
coupler
Check that all couplers are
fully tightened
Air trapped in system
Remove air according to the
instructions 8.3
Cylinder does
not retract,
retracts part
way, or
retracts more
slowly than
normal
Hose I.D. too narrow
Use larger diameter
hydraulic hose
Cylinder retraction
spring brocken
or other cylinder
damage
Have cylinder serviced
by a authorised dealer or
Weitner themselves
If the defects cannot be repaired, contact an authorised dealer or
the service department.
15. Warranty conditions
15.1 Please refer to the general terms and conditions of the
manufacturer.
2.
Technical data
Type
1952 004 001
Order no.
1952 004 001 / Operating pressure
Operating pressure (psi)
5800 - 10150
+ 58
- 14,5
Oil capacity / usable oil
capacity (l)
0,5 / 0,7
Oil delevery HP cm³
2,0 per piston stroke
Dimensions LxBxH (mm)
340 x 100 x 150
Weight with oil (kg)
3,5