6
3.2
Ignition Sequence
SettheOn/Offignitionswitchtothe”ON“
position to release gas.
Push the switch in the
direction of the tip to the
uppermost point to ignite,
then release the switch
back to the ”ON“ posi-
tion.
Do not touch the tip, tip
housing or knurled nut
while igniting.
Do not ignite the device if
”Tip Assembly“ is not
screwed on.
Toturnoff,slidetheOn/Offignitionswitch
downward to the ”OFF“ position.
3.3
CleanorReplaceOrificeAssembly
Remove tip and tip housing by loosening
knurled nut.
While holding the device in a vertical position,
unscrew assembly nozzle (A). You may have to
use pliers or other tool to start unscrewing.
Do not grasp and turn the ceramic head (D).
Carefullyremovetheorificeassembly(B)by
lifting it out of the device (C).
Notethattheshortersideoftheorificeassem-
blyfitsintothedevice.
SoaktheorificeassemblyinNaphthaorother
similar solvent for 5 minutes.
Replacetheclean(ornew)orificeassembly
(shorter side into the device).
Replace the assembly nozzle (hand tighten)
with pliers, grasping the shank of the assembly
nozzle.
Nozzle Assembly
Orifice Assembly
Use mild soap and a damp cloth to clean the
housings of the tool. Do not use household cleaners,
gasoline, turpentine or paint thinner. Never allow
any liquid to get inside of the device. Never immerse
any part of the device in liquid.
4. Cleaning
Summary of Contents for 0984 990 400
Page 26: ...26 3 2 On Off ON ON B On Off OFF 3 3 A D B C 5 A 4...
Page 41: ...41 750 C 20 ml 120 1 2 1 2 2 2 3 2 4 2 5 2 6 2 2 7 2 8 2 9 2 10 50 C 100 0893 250 001 On Off...
Page 42: ...42 3 1 On Off OFF 3 2 On Off ON ON On Off OFF 3 3 A D B C 3 5 4...
Page 49: ...49 750 C 20 120 1 2 1 2 2 2 3 2 4 2 5 2 2 6 2 7 2 8 2 9 2 10 50 C 100 0893 250 001...
Page 50: ...50 3 1 OFF 3 2 ON ON OFF 3 3 x A D B C 5 3 4...
Page 55: ......