Würth 0978 950 006 Quick Installation Manual Download Page 9

LED 

INDICATOR

 

 
To reduce consumption during normal operation, the LEDs are off. In case of anomalies or pressing the PI,  
the indicators are activated for 5 minutes. In the front part a multicolour LED (SL) is installed to indicate the  
various status listed below.

NORMAL OPERATION 

During normal operation the device 
flashes GREEN for 1/4s every 10s.

BOOT PHASE START UP 

A single 1/2s flash indicates the presence of 
correct firmware.

BOOT PHASE START UP 

A fast 1/4s red flash indicates the presence of 
incorrect firmware.

BOOT PHASE START UP 

Red and blue alternating flashing for 2s 
indicates no firmware present.

INTERNAL MEMORY ERROR 

A blue/red flash of 1/2s indicates an error in 
the internal memory of the device.

Summary of Contents for 0978 950 006

Page 1: ...W DOMO DIMMABLE LIGHT MODULE Art 0978 950 006 Quick installation guide...

Page 2: ...m 0 10V which can be used to command control devices such as dimmers for lamps TECHNICAL DATA SHEET Rated supply voltage from BUS 12 V Consumption 30 90 mA max 1W Connections removable screw terminals...

Page 3: ...ce W domo programmable thermostat This cable must comply with CPR regulations while the minimum recommended class is CcA S3 Do A3 To identify the current class of cables for different places of use pl...

Page 4: ...he BUS connection Next to this connector there is the selector for automatic manual operation The PI button is located under the front glass while the LED indicators are next to it The 4 outputs are p...

Page 5: ...o manage the module via smart wifi programmable thermostat In this mode the module contains the function to manage the outputs in dimmer mode with the following pre programmed actions OUT1 controlled...

Page 6: ...MME R VI GND DIMME R VI GND NEUTRO NEUTRO NEUTRO FASE FASE FASE FASE An example of single module manual connection is shown in the figure In manual mode the buttons connected to inputs 1 2 3 and 4 can...

Page 7: ...TRO A B INPUT OUT NEUTRO C C C C 1 2 3 4 5 6 1 2 3 4 PI SL 12 1 2 3 4 5 6 12 M A input 1 input 2 input 3 input 4 apri tutto chiudi tutto 12Vdc 4 3 2 1 out 3 out 4 out 2 out 1 DIMMER VI GND DIMMER VI G...

Page 8: ...n automatic mode connection is shown in the figure In this mode the control of the outputs and the management of the inputs is delegated to the home automation programming A B Home automation PHASE NE...

Page 9: ...low NORMAL OPERATION During normal operation the device flashes GREEN for 1 4s every 10s BOOT PHASE START UP A single 1 2s flash indicates the presence of correct firmware BOOT PHASE START UP A fast 1...

Page 10: ...d to collect the product for disposal free of charge The product does not pose a potential hazard to human health or the environment but if disposed of in the environment it has a negative impact on t...

Page 11: ...Notes...

Page 12: ...isation We reserve the right to modify the products at any time and without notice if the modifications result in a quality improvement The images and photos shown are purely indicative and may not ex...

Reviews: