Installation section for individual installation 

 

Wiring and connection of several master modules 

  

 

Technical data  

Supply voltage 

230V~, +10% / -15%, 50Hz., max. 13VA 

Display 

4-line clear text display with background lighting 
4 x yellow LED menu selection 
1 x red LED, flashing in case of fault 
1 x yellow LED for operating status of communication bus 
1 x yellow LED for operating status of field bus 

Field bus 

3-wire CAN bus interface, shielded, galvanically isolated, 
Push-in terminals 2.5mm² or RJ-45 socket 

Wurm CAN communication bus 

3-wire CAN bus interface, shielded, galvanically isolated, 
Push-in terminals 2.5mm² or RJ-45 socket 

Digital inputs 

6 x 24V=, self-powered, approx. 5mA per input, push-in terminals 
2.5mm² 

Digital outputs 

8 x closing contact with common supply,  
1A, rated voltage 230V~, push-in terminals 2.5mm² 

Dimensions 

(WxHxD) 109 x 109 x 92mm 

Front plate 

Plastic, foil 

Fastening 

In the module frame / individual installation 

Ambient temperature 

0...+50°C operation / -25...+70°C storage 

Weight 

About 650g 

CE conformity 

EC conformity as defined by 

 - 2004/108/EC (EMC Directive) 

   - 2006/95/EC (Low Voltage Directive) 

 

RoHS 

Valid from 

Version 7.0 

 

Summary of Contents for HMS-G3

Page 1: ...e blue lit plain text display with 8 key control panel Up to 32 switching channels for energy consumers 6 direct switching outputs normally open contact Can be extended with up to eight FIO001B FIO PAT field modules Detects the power and the switching of consumers over the communication bus Connection to the Wurm system via a CAN bus connection and Frigodata XP Note Master module HMS G3 is configu...

Page 2: ... out installation wiring or removal work Otherwise a mains voltage may still be present even if the control voltage is switched off The wiring of the device must be carried out only by qualified electricians Use only the correct tools for all work Check all wiring after connection Never expose the device to moisture for example due to condensation or cleaning agents Take the device out of operatio...

Page 3: ...s switched off Installation in the MGR Installation with ZEM Installation in the installation frame MGR131 141 Push the device in the installation frame to the stop until it locks between the spring clips Note Please observe the product information for the MGR131 141 module frame Individual installation with screw clamps of the ZEM type Insert the device up to the stop in a mounting cutout in the ...

Page 4: ... interface shielded galvanically isolated Push in terminals 2 5mm or RJ 45 socket Wurm CAN communication bus 3 wire CAN bus interface shielded galvanically isolated Push in terminals 2 5mm or RJ 45 socket Digital inputs 6 x 24V self powered approx 5mA per input push in terminals 2 5mm Digital outputs 8 x closing contact with common supply 1A rated voltage 230V push in terminals 2 5mm Dimensions Wx...

Reviews: