WURM FRIGOLINK ANI-1F1-A Manual Download Page 4

ANI-1F1-A

4

ANI-1F1-A_V2.5.1_PI_2022-01_EN

Subject to technical changes

FRIGOLINK

A

N

I-1

F1

-A

_V

2.

5.

1_

P

I_

20

22

-0

1_

E

N

.fm

Version and validity of the documentation

Any versions not listed are special solutions for individual projects and are not described in detail in this document.

This document will automatically cease to be valid if a new technical description is issued. 

Manufacturer: 

Wurm GmbH & Co. KG Elektronische Systeme, Morsbachtalstraße 30, D-42857 Remscheid

For further information, see our website at 

www.wurm.de

1.4  Circuit diagram

Fig. 2: Circuit diagram

Power supply

Functional earth (FE)

NOTICE

• To ensure failure-free operation and reliable data communication, connect the functional earth.

Connect the functional earth connection via the enclosed earthing terminal and the pre-assem

-

bled cable directly to the device with the earthed installation plate.

Version

Date

V2.5.1 and 

higher

2022-01

Documentation status

  

   

   

       

         

         

         

         

   

         

   

         

         

         

 

         

         

         

         

˜$

7

æ/%

7

æ/%

7

N"











 











3FMBZ

,

3FMBZ

,,

4PMJE4UBUF

3FMBZ7

7

"OBMPH0VUQVU

6PVU

7

"OBMPH*OQVU

6JO

N"

"OBMPH*OQVU

*JO

%JHJUBM*OQVUT

%*

/

7_



,LQP$9 

%$

 

  

   

   

7

æ/%











 







3FMBZ

,

3FMBZ

,,

4PMJE4UBUF

3FMBZ7

7

"OBMPH0VUQVU

6PVU

       

         

         

         

         

,LQP$9 

7

"OBMPH*OQVU

6JO

7

æ/%

N"

"OBMPH*OQVU

*JO



7

N"



˜$

%JHJUBM*OQVUT

%*

˜$

/

7_



         

         

         

         

   

         

   

         

         

         

Terminal

Power supply

Potential

98

Neutral

N

99

230V~

L

Terminal

Assignment

N

Shield

Summary of Contents for FRIGOLINK ANI-1F1-A

Page 1: ...ation protection function Blocking time after compressor fault 3 step load shedding including Fastreturn Operating hours counter and cycle counter for each compressor Proactive oil return High pressur...

Page 2: ...4 Functional earth FE 4 1 4 1 Input circuit diagram 5 Digital inputs DI 1 DI 20 5 Analogue inputs Uin 1 2 6 Analogue inputs Iin 1 Iin 5 6 Analogue inputs S 1 S 16 7 1 4 2 Output circuit diagram 8 Digi...

Page 3: ...intended purpose WARNING DANGER TO LIFE FROM ELECTRIC SHOCK AND OR FIRE Switch off the power to the entire plant when carrying out installation wiring or disassembly work Otherwise mains voltage and o...

Page 4: ...1 4 Circuit diagram Fig 2 Circuit diagram Power supply Functional earth FE NOTICE To ensure failure free operation and reliable data communication connect the functional earth Connect the functional e...

Page 5: ...7 N JHJUBM OQVUT 7_ Terminal Digital input Potential Assignment 101 DI 1 230V Not available 111 N 102 DI 2 230V Night signal 112 N 103 DI 3 230V Load shedding 1 113 N 104 DI 4 230V HR request 114 N 1...

Page 6: ...230V HP rack fault 137 N 128 DI 18 230V GC fan fault 138 N 129 DI 19 230V Alarm input 1 NC 139 N 130 DI 20 230V Alarm input 2 NC 140 N Terminal Analogue input Potential Assignment 41 Uin 1 GND Not av...

Page 7: ...t 161 162 S 1 TRK Ts MT 163 164 S 2 DGF MT T hg 165 166 S 3 DGF LT T dsh 167 168 S 4 TRK T out 169 170 S 5 DGF T gc 1 171 172 S 6 DGF T gc 2 173 174 S 7 DGF HR CO2 T outlet 175 176 S 8 DGF HR medium T...

Page 8: ...1 202 NC 203 NO 204 Change over contact K 2 4 2 A 230V COM Alarm prio 2 205 NC 206 NO 207 NO contact K 3 3 1 A 230V COM MT CP 1 operation 208 NO 209 NO contact K 4 3 1 A 230V COM MT CP 2 operation 210...

Page 9: ...ment Assignment 231 Semiconductor V 1 4 60VA 230V NO HG bypass 232 COM 233 Semiconductor V 2 4 60VA 230V NO Liquid injection 234 COM 235 Semiconductor V 3 4 60VA 230V NO Constant liquid injec tion 236...

Page 10: ...4 3 Communication circuit diagram Fig 5 Communication circuit diagram Communication 7 7 7 N 3FMBZ 3FMBZ 4PMJE 4UBUF 3FMBZ 7 7 OBMPH 0VUQVU 6PVU 7 OBMPH OQVU 6JO N OBMPH OQVU JO JHJUBM OQVUT 7_ LQ P 9...

Page 11: ...voltage is switched off Top hat rail installation 1 There are 2 fastening safety catches located on the back of the module A Press both fastening safety catches a downward until they engage with a cl...

Page 12: ...red operating voltage green fault red 4 x LED green CAN bus data traffic CAN Tx CAN Rx Sensors 16 x DGF TRK C BUS communication 3 conductor CAN bus interface shielded galvanically isolated screw term...

Reviews: