WURM ANI-2F1 Manual Download Page 5

ANI-2F1

ANI-2F1_V1.0.4_PI_2020-06_EN

5

Subject to technical changes

FRIGOLINK

1.4  Circuit diagram

Fig. 2: ANI-2F1 circuit diagram

Power supply

Functional earth (FE)

NOTICE

• To ensure failure-free operation and reliable data communication, connect the functional earth.

Make the functional earth connection using the enclosed earthing terminal and connect the patch

cable directly to the device using the earthed installation plate.

11 12 13 14

71 72 73 74

81 82 83 84

238 237 236 235 234 233 232 231

250 249 248 247 246 245 244 243 242 241

201 202 203 204 205 206 207 208 209 210

44 43 42 41

151 152 153 154 155 156 157 158 159 160

194 193 192 191

170 169 168 167 166 165 164 163 162 161

98 99

140 139 138 137 136 135 134 133 132 131

120 119 118 117 116 115 114 113 112 111

130 129 128 127 126 125 124 123 122 121

110 109 108 107 106 105 104 103 102 101

µC

RS 485

PE

11

14

F-BUS

LAN

71

F-BUS

74

C-BUS

C-BUS

C-BUS

81

84

250

Uout 5...1 / 0-10V

241

V 4...1 / each 60VA max.

238

231

K 5...9 / each 4(2)A@230V~

211

201

210

K 1...4 / each 4(2)A@230V~

220

K 10...14 / each 4(2)A@230V~

221

230

S16

194

S 15...11 / Sensor

190

191

181

S 10...6 / Sensor

180

171 170

S 5...1 / Sensor

161

Iin 1...5 / 4-20mA

160

151

Uin 2, 1 / 0-10V

44

41

0-10V

GND

0-10V

GND

24V=

4-20mA

207,209
211,213
215,217
219,221
223,225
227,229

208,210
212,214
216,218
220,222
224,226
228,230

202,205

203,206

231,233
235,237

232,234
236,238

241,243
245,247
249

242,244
246,248
250

201,204

44,42

43,41

152,154
156,158
160

151,153
155,157
159

N

230V~

101-110
121-130

111-120
131-140

Relay

K 3-14

Relay

K1,K2

Solid State

Relay V 1-4

0-10V

Analog Output

Uout 1-5

0-10V

Analog Input

Uin 1, 2

4-20mA

Analog Input

Iin 1-5

Digital Inputs

DI 1-20

230V~/50Hz

140
130

N 20...11 / neutral terminal

DI 10...1 / 230V~

120
110

131
121

111

101

DI 20...11 / 230V~

N 10...1 / neutral terminal

N

S 15...11 / Sensor

190

181

S 10...6 / Sensor

180

171

K 5...9 / each 4(2)A@230V~

211

220

K 10...14 / each 4(2)A@230V~

221

230

max. 20VA

71421135B

ANIMUS    ANI-2F1

part of Frigolink

7A451261

71421

139

7B451061A

N

98 99

230V~/50Hz

RS 485

PE

11

14

F-BUS

LAN

71

F-BUS

74

C-BUS

C-BUS

C-BUS

81

84

11 12 13 14

71 72 73 74

81 82 83 84

250

Uout 5...1 / 0-10V

241

V 4...1 / each 60VA max.

238

231

201

210

K 1...4 / each 4(2)A@230V~

0-10V

GND

207,209
211,213
215,217
219,221
223,225
227,229

208,210
212,214
216,218
220,222
224,226
228,230

202,205

203,206

231,233
235,237

232,234
236,238

241,243
245,247
249

242,244
246,248
250

Relay

K 3-14

Relay

K1,K2

Solid State

Relay V 1-4

0-10V

Analog Output

Uout 1-5

201,204

238 237 236 235

248 247 246 245 244 243 242 241

202 203

205 206 207 208 209 210

234 233 232 231

250 249

201

204

S16

194

191

170

S 5...1 / Sensor

161

Iin 1...5 / 4-20mA

160

151

Uin 2, 1 / 0-10V

44

41

0-10V

Analog Input

Uin 1, 2

44,42

43,41

0-10V

GND

4-20mA

Analog Input

Iin 1-5

152,154
156,158
160

24V=

4-20mA

151,153
155,157
159

N

230V~

µC

101-110
121-130

111-120
131-140

Digital Inputs

DI 1-20

µC

130

N 20...11 / neutral terminal

110

121

N 10...1 / neutral terminal

101

DI 20...11 / 230V~

140

DI 10...1 / 230V~

120

131

111

140 139 138 137 136 135 134

131

130 129 128 127 126 125 124

121

120

117 116

113 112 111

110

107 106

103 102 101

44 43 42 41

151 152 153 154 155 156

194 193

192 191

170 169 168 167

162 161

133 132

123 122

119 118

115 114

109 108

105 104

166 165 164 163

157 158 159 160

Terminal

Power supply

Potential

98

Neutral

N

99

230V~

L

Terminal

Assignment

N

Shield

Summary of Contents for ANI-2F1

Page 1: ...C compressors 2 directly controlled FC compressor based on best COP Monitoring of suction gas temperature Oscillation protection function Blocking time after compressor fault 3 step load shedding incl...

Page 2: ...t circuit diagram 6 Digital inputs DI 1 DI 20 6 Analogue inputs Voltage Uin 1 Uin 2 7 Analogue inputs Current Iin 1 Iin 5 7 Analogue inputs Sensors S 1 S 16 7 1 4 2 Output circuit diagram 8 Digital ou...

Page 3: ...NG DANGER TO LIFE FROM ELECTRIC SHOCK AND OR FIRE Switch off the power to the entire plant when carrying out installation wiring or removal work Otherwise a mains voltage and or external voltage may s...

Page 4: ...ns for individual projects and are not described in detail in this document This document automatically ceases to be valid if a new technical description is issued Manufacturer Wurm GmbH Co KG Elektro...

Page 5: ...4 0 10V Analog Output Uout 1 5 0 10V Analog Input Uin 1 2 4 20mA Analog Input Iin 1 5 Digital Inputs DI 1 20 230V 50Hz 140 130 N 20 11 neutral terminal DI 10 1 230V 120 110 131 121 111 101 DI 20 11 23...

Page 6: ...Output Uout 1 5 0 10V Analog Input Uin 1 2 4 20mA Analog Input Iin 1 5 Digital Inputs DI 1 20 230V 50Hz 140 130 N 20 11 neutral terminal DI 10 1 230V 120 110 131 121 111 101 DI 20 11 230V N 10 1 neutr...

Page 7: ...ND Not available 42 0 10V 43 Uin 2 GND Not available 44 0 10V Terminal Analogue input Potential Assignment 151 Iin 1 4 20mA p0 MT 1 152 24V 153 Iin 2 4 20mA p mp 154 24V 155 Iin 3 4 20mA p gc 156 24V...

Page 8: ...30V 101 110 121 130 111 120 131 140 Relay K 3 14 Relay K1 K2 Solid State Relay V 1 4 0 10V Analog Output Uout 1 5 0 10V Analog Input Uin 1 2 4 20mA Analog Input Iin 1 5 Digital Inputs DI 1 20 230V 50H...

Page 9: ...e ment Assignment 231 232 V 1 Not used 233 234 V 2 Not used 235 Semiconductor V 3 4 60VA 230V NO Not available 236 237 Semiconductor V 4 4 60VA 230V NO Not available 238 COM Terminal Analogue output P...

Page 10: ...S16 194 S 15 11 Sensor 190 191 181 S 10 6 Sensor 180 171 170 S 5 1 Sensor 161 Iin 1 5 4 20mA 160 151 Uin 2 1 0 10V 44 41 0 10V GND 0 10V GND 24V 4 20mA 207 209 211 213 215 217 219 221 223 225 227 229...

Page 11: ...off Top hat rail installation 1 There are 2 fastening safety catches located on the back of the module A Press both fastening safety catches a downward until they engage with a click 2 There are 4 ret...

Page 12: ...1 x LED green red operating voltage green fault red 4 x LED green CAN bus data traffic CAN Tx CAN Rx Sensors 4 x DGF TRK C BUS communication 3 wire CAN bus interface shielded galvanically isolated sc...