11. WARNING INFORMATION 

       

1.Low battery indication This warning show that the voltage of battery is very low, please change 
a new one.   

 

2. The loading is over limit when power on, please reduce the loading. 

 

3. The loading is under limit when power on, please increasing the loading. 

 

4. Over load or Counting error

 

The  loading  is  over  limit  when  power  on,  please  reduce  the  loading  and  try  again.  If  the 

trouble is still exist, please call the service.   

 

5. Counting error (too low)

 

The loading is lower than limit when power on, please increase the loading and try again. If 

the trouble is still exist, please call the service.

 

 

6.EEPROM error-- 

The programs of the scale is error, please call the service.   

 

 

12. CLEANING & MAINTENANCE 

  We would recommend using alcohol based wipes or similar when cleaning the scales.    Please do not use 

large  amounts  of  water  when  cleaning  the  scales  as  this  will  cause  damage  to  the  scales  electronics,  you 

should  also  refrain  from  using  corrosive  liquids  or  high  pressure  washers.    Always  disconnect  the  scales 

from the mains power supply before cleaning. 

The machine is sold approved with first metrological test passed (plate with green M). If required, the first 

periodic test (green label) can be performed by the manufacturer. At the expiry date indicated on the green 

label,  the  periodic  test  must  be performed  on  the  machine.  Subsequent  calibration  is  always  necessary,  if 

one or more safety markings are damaged or the display shows abnormal weights. Always have maintenance 

performed by qualified personnel. The WUNDER customer technical support service is at your disposal. 

      ATTENTION! 

In some countries, calibration can be performed only by an authorised/qualified agent. Contact your dealer for 

further 

 

13. DISPOSAL OF THE SCALE 

EU 2002/96/EC   

This product complies with EU Directive 2002/96/EC. The symbol of the barred waste basket shown on the 

appliance indicates that this product, which, must be treated separately from domestic refuse at the end of 

its useful lifetime, must be taken to a differentiated collection centre for electrical and electronic devices, or 

returned  to  the  dealer  when  a  new  equivalent  device  is  purchased.  The  user  is  responsible  for  taking  the 

appliance to the appropriate collection facility at the end of its lifetime. Appropriate differentiated collection 

for submitting the used appliance to environmentally compatible recycling, treatment, and disposal helps to 

Summary of Contents for RS300

Page 1: ... using the instrument INDEX 2 GENERAL RULES 2 3 SAFETY 3 4 FEATURES 7 5 KEY PANNEL 7 6 WEIGHING OPERATION 8 7 FUNCTIONS SETTING 9 8 OPERATION FLOW 9 9 SETTING UP YOUR SCALE STEP BY STEP 10 10 INSTRUCTION FOR BATTERY INSTALLATION 10 11 WARNING INFORMATION 11 12 CLEANING MAINTENANCE 11 13 DISPOSAL OF THE SCALE 11 14 WARRANTY LIABILITY 12 15 IDENTIFICATION PLATES 12 ...

Page 2: ... the instrument as it supplies important indications concerning OPERATING SAFETY AND MAINTENANCE The descriptions and illustrations supplied in this manual are not binding WUNDER reserves the right to modify its products as deemed convenient in order to approve them without being committed to update this publication Conventions The following symbols have been used in this manual 0476 EC TYPE APROV...

Page 3: ...assembling phase and before weighing operations the operator must be sure that RS300 dynamometer and the sling are on VERTICAL POSITION During weighing operation the hanging sick lift scale is not moving The operator must ALWAYS follow and hold the sling of the patient during lifting phase to avoid torsion and sudden movement of both dynamometer and sling that could cause breakages and irreparable...

Page 4: ...and the user should ensure that it is used in that environment Emission test Conformity Guide to electromagnetic environment RF Emission CISPR11 Group 1 Class B The scales RS300 cable model uses RF energy only for its internal function The refore its RF emissions are very low and probably not cause no interference in electrical equipment RF Emission CISPR11 Group 1 Class B The scales RS300 is suit...

Page 5: ...ow Emissions test Compliance Guide to electromagnetic environment Radiated conducted emissions IEC EN61000 4 6 3Vrms 150kHz to 80MHz for appliances that are not life supporting Equipment in RF communications and mobile laptops should ot be used near any part of the tooth including cables except when they meet the recommended separation distance calculated by the frequency applied to the transmitte...

Page 6: ...cted to operate in an electromagnetic environment in which they control the noise radiated RF The customer or the tooth may be of help to prevent electromagnetic interference by ensuring a minimum distance between mobile communication devices and portable RF transmitters and unity as recommended below with respect to the maximum power output of equipment radio Output power rating of the transmitte...

Page 7: ...5 KEY PANNEL FUNZIONI RS300 HOLD Indicatore blocco peso NET peso netto GROSS peso lordo kg unità Kg 1 ON OFF ZERO TARE 1 Switch on off the scale 2 Press this key to zero the scale The zero range is 2 of full capacity 3 Press this key to tare when loads over zero range 4 In tare mode press this key again to clear the tarred value when there is no load on the platform 5 Press this key without releas...

Page 8: ...TTENTION Tilt angle over 3 will cause false reading During weighing phase by means of RS dynamometer the operator must be sure that the patient remains still to avoid any instruments torsion and the following uncorrect weighing We recommend to not use any lift or Hoist that hanger bar do not swivel 360 degrees After assembly at the lifter the dynamometer must not be rotated horizontally Rotation i...

Page 9: ...ec off Buzzer Adjustment This function affects the buzzer sound ON and OFF by user s preference Buzzer On Off 8 OPERATION FLOW A OFF BEEP End On Off 120 180 240 300 Off Setting the time for auto time off 120 180 240 300 off seconds Buzzer ON beep on OFF beep off Save the settings Press and hold Hold key for 3 seconds Display shows Set Notice Hold means select jump to another selection horizontally...

Page 10: ...ress HOLD to shift to BEEP setup mode Step 5 Press ZERO to enter BEEP setup mode and press HOLD again to select between ON and OFF Step 6 Press ZERO to decide and return to BEEP setup mode Step 7 Press HOLD to select END and press ZERO to finish setting 10 INSTRUCTION FOR BATTERY INSTALLATION RS uses six AAA size alkaline batteries Please read the following instruction before using the scale 1 Fin...

Page 11: ...hine is sold approved with first metrological test passed plate with green M If required the first periodic test green label can be performed by the manufacturer At the expiry date indicated on the green label the periodic test must be performed on the machine Subsequent calibration is always necessary if one or more safety markings are damaged or the display shows abnormal weights Always have mai...

Page 12: ...ium Hg Hg batteries that contain mercury ATTENTION Do not throw the electrical parts or batteries into the household waste Dispose of the batteries at the collection centres in your area 14 WARRANTY LIABILITY WUNDER products are guaranteed under warranty The warranty is valid for faults or malfunctions of the instrument due to manufacturing or material defects and WUNDER reserves the right to repa...

Page 13: ...WUNDER SA BI SRL EN USER MANUAL RS 300 REV 01 10 01 2017 13 ...

Reviews: