TReX User Manual v15.30 Firmware
To send “WT1234560A10 test” out the serial port:
WTS
WT1234560A10 INPUT 1 LOW
<CR>
The WTS serial output message type also supports sending of any non-printable character.
When the ‘$’ is seen, the following 2 characters are treated as hex.
To send 3 non-printable characters <SOH><STX><ETX> out the serial port:
WTS
$
01
$
02
$
03<CR>
$W1 and $W2 are also accepted, :
•
$W1 – first comma separated field in last processed WT protocol payload.
•
$W1 – second comma separated field in last processed WT protocol payload.
For the sequence:
1. Message of
WT0000000A10 FIRST,SECOND
is processed
2. Message of WTStest$0Doutput$W1and$W2<CR> is received
the serial output will be:
test<CR>outputFIRSTandSECOND
4 Level Modulations
All WTE 4L modulations, regardless of the used channel spacing, transmit data using the
WTE_EN transport method. 4L modulations also do not include forward error correction
information as all 2L modulation supported do. This gives much faster possible transmission
speeds.
To transmit a 16000 baud, 12.5kHz channel message:
WT1234560
W
1G test message<CR>
Ensure the receiving TReX has the RF->MODE configured to WTE_EN
Support for Multiple Messages
The WT protocol allows for the same message to be sent to a variety of different radio types.
This allows for an efficient way to send to several different RIC codes or technology types.
Many message transmissions can be supported, until the max message length for the message
© WTE Limited, 2022 – Christchurch New Zealand
Page 145 of 302
Summary of Contents for TReX-460
Page 87: ...TReX User Manual v15 30 Firmware WTE Limited 2022 Christchurch New Zealand Page 87 of 302...
Page 286: ...TReX User Manual v15 30 Firmware WTE Limited 2022 Christchurch New Zealand Page 286 of 302...
Page 302: ...TReX User Manual v15 30 Firmware WTE Limited 2022 Christchurch New Zealand Page 302 of 302...