background image

I

P

system gate station installation manual 

 

 

I Z M - 8 0 1 C S 4

R

Ty

pe

:B/

B,I

Thank you for choosing WRT. Please read this manual before 
using. WRT reserves the right to change specifications or designs 
described in this manual without notice and obligation.

Summary of Contents for IZM-801CS4

Page 1: ...n installation manual IZM 801CS4 R Type B B I Thank you for choosing WRT Please read this manual before using WRT reserves the right to change specifications or designs described in this manual without notice and obligation ...

Page 2: ...nt 1 0 Features Functions 2 0 Equipment Description Gate Station 3 0 Caution 4 0 Installation 5 0 Operation 6 0 Specification 7 0 Terminal Description 8 0 Trouble Shooting 9 0 Wiring 1 2 2 3 4 5 6 22 23 24 25 26 28 ...

Page 3: ...CD Display 4 Digital audio video coding 5 Multichannel Guard Center can call other spare door phones while Gate Station are talking with door phone 6 Divert No Disturb multi monitors and multi centers choose center automatically 7 Can call talk with Guard Center which can remote unlock 8 Unlock by password or cards disarm by cards 9 function optional Snapshot 10 Burglar alarm optional D 11 oor con...

Page 4: ...zone 7 Camera adjustment 8 Socket for lift control or access control 9 Lightning terminal GND 10 Socket for power input unlock signal output 11 To network switch connector 12 Socket for door contact and door release Front View Back View 2 1 5 6 3 4 7 8 12 9 GND 11 10 18V GND MENCI DOOR GND UNLOCK B A J13 J15 J21 J24 J20 J22 EARTH GND ...

Page 5: ...it is lightening terminal should be earthing any one is ok so as to avoid undesirable effects 8 In order to avoid interference it is better to use wire tube and separate other interferences For easy maintenance and stability all wire ends should not be installed in the wire tube or place where is humid 9 Turn on the power supply after installing the whole system well 10 Keep IC card be water resis...

Page 6: ...ble place on the front and the back of the door according to the size Figure 1 2 Unscrew 4 screws from Gate Station Figure 2 Drill a wire hole at the bottom case insert the transmission wires through the wiring hole 3 Connecting all wires and press the Gate Station from the front of the door Fix the bottom case with screws 4 Fix Gate Station with screws ...

Page 7: ...a wiring hole on the bottom case and insert the wires through it install the bottom case 2 into the wall and embed it in the cement 3 Unscrew 4 screws from Gate Station and separate aluminium sheet 4 Connecting all Gate Station wires then fix Gate Station on the bottom cover 5 Fix the aluminium sheet with screws Wall 1 2 3 4 135mm 380mm Wire tube 67 0mm Wall Bottom case ...

Page 8: ...copied data file in case of any damage of computer system 4 Every twice press the button not more than 30s or it will exit operating state When standby the screen will show The Gate Station works after all parameters are correct Press first then press and release the two keys at the same time The screen will show Input 1 8 digits managing PIN setting last time If it is first time to input it shoul...

Page 9: ...k parameter Press 1 on the basic setting menu the screen shows 1SN 2MAC 3VER 4Device ID 5Local IP 6Subnet mask 7Gateway Press to return Press to next page 0 System info 5 Password setting 1 Network setting 6 Function ON OFF 2 Device No 7 Time setting 3 Dial Format 8 Access control 4 Device type 9 Language 1 Restore factory setting 2 Restart 3 Return 0 Next page 2 00 10 00 00 00 00 00 00 Ba00000001...

Page 10: ... Station etc other IP address no need to input Press to clear up the data in the input box or exit input status Device NO Press 2 on the basic setting menu the screen shows Press number keys it can clear up the data in the related input box and input network parameters according to actual distribution After finished input the data each time press to confirm the screen will prompt that modify succe...

Page 11: ...nput status Dial Format Press 3 on the basic setting menu the screen shows Room NO of tenant adopt 13 digit encode 2 digit group NO 3 digit building NO 2 digit unit NO 3 digit floor NO 3 digit room NO For example group NO digit is 0 building NO digit is 0 unit NO digit is 0 floor NO digit is 1 room NO digit is 1 when Gate Station calls floor 1 room 1 input 11 can call this tenant If floor NO digit...

Page 12: ...basic setting menu the screen shows Press the device you want means selected press to confirm the screen will prompt modify successfully Press to return to previous menu Password setting set local super password and unlock password Press 5 on the basic setting menu the screen will show Room NO Room NO Operation 1 Entrance Station 2 Main Gate Station 3 Sub Gate Station 4 Return 10 Operation 1 Modif...

Page 13: ...o new super passwords are the same it will prompt that new super password is modified successfully Note Original password is 88888888 Must use new password when enter setting menu b Modify unlock password Press 2 on password setting interface to the menu Please input new password Operation Operation Please input new password ...

Page 14: ...00 c Modify special password Press 3 on password setting interface to the menu Input room NO Former 3 digit is floor NO last 3 digit is room NO press to confirm the screen shows Input 6 digits new password press to confirm Then the screen prompt to confirm special password again tenant input new password again press to confirm If entered two new special passwords are the same it will prompt that n...

Page 15: ...N OFF When this function enabled on IP door phone and Gate Station Gate Station can leave message for the tenant Magnetic alarm When Gate Station is connecting with door contact enable magnetic alarm is sug gested Thus if door release exceed delay time of door contact and not close the door it will report the alarm to Guard Center Press number keys to clear up the data in the input box Input 0 or ...

Page 16: ...group data set successfully Under non input state press 3 or to return previous or exit automatically after 30s Access control It is effective for Gate Station with access control including issue card by room NO issue card by swiping delete card by room NO and delete card by swiping 1 Issue card by swiping 2 Delete card by swiping 3 Issue card by room NO 4 Delete card by room NO 5 Return 1Input Ye...

Page 17: ...rface the screen will show Swipe the card at the induction zone according to the prompt the screen prompts modified successfully it means the card deleted successfully the user could continue deleting other cards Press to return to previous menu c Issue card by room NO Issue card by room NO of the tenant Press 3 on the Access Control interface the screen will show 1 Issue card by swiping 2 Delete ...

Page 18: ... for example 001001 the room NO of tenant 3 digit floor NO 3 digit room NO Then press to confirm it means deleted successfully Note The tenant could use the card which is issued successfully to unlock The card which is deleted will become invaildly can not open the electric lock until the card is registered again Language There are two languages for option English and Chinese 1 Issue card by swipi...

Page 19: ...e initialized Gate Station will restart automatically Restart Press 2 on the basic setting menu on page 2 the screen will show Press 1 then press Gate Station will restart automatically Volume setting Press 3 on the basic setting menu on page 2 the screen will show 0 NO 1 YES Restore factory setting 0 NO 1 YES Restart Operation Operation 0 9 1 Ring volume 2 Talk volume 3 Return 5 5 ...

Page 20: ...4 on the basic setting menu on page 2 the screen will show Press 1 to clear up the data in the input box Input delay time Max 300 press to confirm the screen will prompt that modify successfully Press to exit input status or to return to previous menu or exit automatically after 30s Non input status press 2 Room format Press 5 on the basic setting menu on page 2 the screen will show Operation 18 O...

Page 21: ...box or exit input status Magnetic Alarm There is a magnetic terminal ENC ocket J he back of Gate Station M I GND on the s 24 which is at t it is used to connect magnetic when ENC M I and GND are open more than the magnetic delay time and no short circuit it will report the alarm no short circuit it will report alarm Note DOOR and GND on the s 24 which is at t There is a magnetic terminal ocket J h...

Page 22: ...302 the screen display the corresponding number at the same time After finished input the room number press to confirm if the number does not exist the screen will prompt If the number is correct and the line is not busy it will ring out the screen will show When the tenant answers the phone the screen will show Input room NO for call 00 for center Room NO does not exit Calling to hang up 0302 Ope...

Page 23: ...g the tenant door phone is IP system and Gate Station with message function if time out and no one answer the call Gate Station will prompt Press to leave a mess age in 5s others to hang up visitor can press to leave message for tenant the screen display the countdown Calling Tenants Divert on When the station calls the tenant and the line is not busy the system will transfer the call to Guard Ope...

Page 24: ...ly If someone answers the call can last 120 seconds Unlock the door by Guard Center while talking If divert on it will transfer the call to the Center If the Center no answer or is busy it will transfer the call to the Back up Center If the Center is busy no Back up Center it will prompt busy tone please call later Unlock by password If the device is Entrance Station tenant could unlock by passwor...

Page 25: ...oom 1 The tenant with spe cial password is 000002 should input 11000002 Unlock by Access Control card When standby the tenant use IC card to close to the induction zone Du tone can be heard if succeed the screen will show If IC card fails validation Du Du tone can be heard the screen will prompt invalid card Input room NO for call 00 for center Unlock please close the door Operation Input room NO ...

Page 26: ...Network port Protocol Wiring distance IC Access Time IC Access Distance Capacity of cards Protection Grade Dimensions Size of Bottom case 18VDC 290mA About 120s 45 95 5 mA 370 IP33 147 393 80 I mm ncluding bottom case 133 377 65mm 30 C 55 C 0 0 30mV 20mm RJ45 TCP IP Use a network switch or router in 100m add a fiber optical transceiver over 1 100ms 3000 320 RGB x240 4 0 inch 5 16U 500 wire Automat...

Page 27: ...Description UNLOCK GND 18V DOOR GND MENIC A B GND J24 J20 J13 J21 Power supply input supply DC 18V for the station Power supply input Unlock signal output 12V when unlock Unlock signal input GND To door contact 485A data wire 485B data wire GND To network switch ...

Page 28: ...upply 2 Check if electric lock is match 3 Check connection of network wire 1 Use PIN to release door if it works the problem is the wiring between Gate Station and system 2 If PIN cannot release door please test if there is 12V between LOCK of Gate Station and NO port of system power supply when release door If no voltage in LOCK please change Gate Station If there is voltage in NO please change e...

Page 29: ...please connect according to actual situation Back view GND 18V GND MENCI DOOR GND GND UNLOCK B B A A J13 J15 J21 J24 J20 J22 EARTH GND Wire of power supply Wire of electric lock 18V GND PUSH NO NC Electric lock HD V18 To lift controller or access control To network switch GND Door contact Door release ...

Page 30: ... Add WRT Industrial Base Dafu Industrial Park Guanguang Rd GuanLan Town BaoAn District ShenZhen China Tel 86 755 29576113 Fax 86 755 29576023 Http www wrtsz com Shenzhen WRT Intelligent Electrical Appliance Co Ltd ...

Reviews: