background image

Nanoliter 2010 with SMARTouch™ Controller

World Precision Instruments 

1

Get started with your Nanoliter 2010 and SMARTouch™ Controller as quickly as 

possible using these step by step instructions.

NOTE

: This Quick Start Guide assumes that the operator back filled a micropipette 

with mineral oil. For instructions on how to prepare the micropipette, see the 

Nanoliter2010 Instruction Manual page 7.
1.  Connect the AC power cord to the power supply unit and connect the power 

supply unit to the MICRO2T controller. Plug the AC power cord into a wall outlet.

  

 
2  Connect the Nanoliter adapter cable to the output of channel 1 of the 

SMARTouch™ controller and the RJ-11 connector of the Nanoliter2010 to the 

RJ-11 female connector on the adapter. Make sure the embossed arrow on the 

connector is facing upwards for proper pin alignment.

 

Adapter Cable connects to the 

SMARTouch™ controller

Nanoliter 2010 Injector connection to 

the adaper.

Summary of Contents for NANOLITER2010

Page 1: ...Instrumenting scienti c ideas WORLD PRECISION INSTRUMENTS NANOLITER2010 Nanoliter Injector with SMARTouch Controller Serial No _____________________ www wpiinc com QUICK START GUIDE 061217...

Page 2: ...17 by World Precision Instruments All rights reserved No part of this publication may be reproduced or translated into any language in any form without prior written permission of World Precision Inst...

Page 3: ...er2010 Instruction Manual page 7 1 Connect the AC power cord to the power supply unit and connect the power supply unit to the MICRO2T controller Plug the AC power cord into a wall outlet 2 Connect th...

Page 4: ...n the unit The following screen appears 4 Touch the Initial Splash Screen anywhere The MAIN MENU appears Touch DISPLAY ALL CHANNELS 5 The syringe status screen appears Press anywhere in the PUMP1 Disp...

Page 5: ...h the Configure button 7 Press the Type box to bring up the Syringe Selection Screen 8 In the Syringe Selection Screen press the DWN key until you see the NL Nanoliter 2010 type and press it It will b...

Page 6: ...FIGURATION screen appears Touch the Volume Target display 10 The Volume Target screen appears Use the numerical keypad to enter 2500 nL Touch ENTER to set the volume and return to the CONFIGURATION sc...

Page 7: ...ery rate and return to the CONFIGURATION screen 13 The Configuration screen shows that a target volume of 2500 nL was entered and a delivery rate of 500 nL s was entered Touch BACK to return to the sy...

Page 8: ...s will place the metal needle plunger about 13 6 mm from the home fully retracted position At this point install the back filled micropipette on to the Nanoliter2010 injector as shown below 16 Press t...

Page 9: ...ecision Instruments 7 18 Press the Volume Target area to bring up the Volume Target screen 19 Use the keypad to enter the desired aliquot volume to be pulled into the micropipette We will enter 200 nL...

Page 10: ...he keypad to set the rate to 50 nL sec and press Enter 22 Press Back to go to the main Syringe information display 23 Next place the micropipette tip into the aliquot to be loaded and press RUN This w...

Page 11: ...4 When the injector finishes press the direction button to set it to Infuse The arrow will turn Red 25 Now the micropipette can be placed at the desired injection location and after setting the desire...

Page 12: ...com Germany Zossener Str 55 10961 Berlin Tel 030 6188845 Fax 030 6188670 E mail wpide wpi europe com China Hong Kong WPI Shanghai Trading Co Ltd Rm 25e No8 Dongfang Rd Pudong District Shanghai 200120...

Reviews: