background image

Rev 19.3/9-18 

18 

VL411LDC: #35162 

 

B

ATTERY 

R

ECHARGE

 

Charge the battery whenever the battery gauge indicates diminished energy (see B

ATTERY 

T

EST

 

preceding).   

CAUTION: Make sure valve handle is in “release” position (power OFF). 

Identify the input voltage marked on the battery charger, and plug it in to an appropriate power 

source.

9

    A ground fault circuit interrupter is necessary to reduce the risk of electrical shocks. 

WARNING:    Make sure power source is equipped with ground fault circuit 

interrupter. 

The power lamp (Ф) turns on, to indicate 

that the charger is functioning.    To 
determine charging status, consult the six-
stage display on the charger.    The battery is 

ready for use at stage 3 and fully charged at 
stage 5. 
Normally, the battery should take no more 

than 8 hours to charge completely.

10

    If not, 

check for the following conditions and 

correct any deficiencies as directed: 
• Power lamp (Ф) flashes:    Charger is not connected to battery; reconnect charger (see 

ASSEMBLY). 

• Error lamp (!) turns on:    Battery leads connected to the wrong poles; reverse battery leads. 
• Error lamp (!) turns on and charging stops at stage 1 or stage 4:    Battery is no longer 

functioning; replace battery (see REPLACEMENT PARTS LIST). 

Be sure to unplug the charger and test the battery energy again before operating the lifter (see 

B

ATTERY 

T

EST

 preceding). 

V

ACUUM 

P

AD 

M

AINTENANCE

 

Friction Coefficient 

The friction coefficient represents the lifter's ability to resist load slippage when the load is 

oriented in any position except horizontal.    If the contact surfaces of either the load or the 
vacuum pads are not clean, dry and in good condition, slippage is more likely to occur. 
The Load Capacity of most Powr-Grip lifters is based on a friction coefficient of 1 (only Flat Lifters 

are exempt from this requirement).    However, a vacuum pad's ability to maintain this friction 

coefficient is reduced by factors such as contamination, wear, age and exposure to sunlight, as 
well as the condition of the load's contact surface (see INTENDED USE: L

OAD 

C

HARACTERISTICS

).   

Pads that have surface contamination must be thoroughly cleaned (see Cleaning discussion to 

follow).    Over time, the rubber in a pad may experience hardening or leaching of chemicals, 

                                        

9

    Any external power supply must conform to all applicable local codes.   

CAUTION: Do not operate the lifter while the 

charger is connected to an AC power source

, since this could result in permanent damage to the charger. 

10

    The charger is designed to automatically sense the energy level of the battery and reduce the charging rate when the battery 

is fully charged.    Accordingly, the charger does not need to be unplugged until the lifter is going to be used again. 

Summary of Contents for VL411LDC

Page 1: ...________ please see serial label and record number here VERTICAL LIFTER 700 DC VOLTAGE READ ALL INSTRUCTIONS AND WARNINGS BEFORE OPERATING THIS LIFTER DESIGNED FOR THE MATERIALS HANDLING PROFESSIONAL...

Page 2: ......

Page 3: ...eading the Vacuum Gauge 11 Vacuum Level on Optimal Surfaces 11 Vacuum Level on Other Surfaces 11 TO LIFT AND MOVE THE LOAD 12 Load Capacity and the Warning Light 12 Monitoring Vacuum Indicators 12 Mon...

Page 4: ...Procedures 21 VACUUM PUMP MAINTENANCE DYNAFLO DV1032102 22 Replacing the Diaphragm 22 Replacing the Head Assembly 22 VACUUM PUMP MAINTENANCE THOMAS 107CDC20 23 Replacing the Diaphragm 23 Replacing the...

Page 5: ...load weight higher than 16 Hg 54 kPa and whenever vacuum loss causes pump to re engage Low Vacuum Warning Buzzer if applicable Maximum Alarm Volume 103 dBA at 2 60 cm While lifter is powered up audibl...

Page 6: ...y or attempt to lift loads that the lifter is not designed for see INTENDED USE LOAD CHARACTERISTICS Never attempt to lift cracked or broken glass with this lifter Always position the vacuum pads corr...

Page 7: ...heir first appearance in each section Standard VL411LDC shown 1 LIFT SLING 6 Enclosure with VACUUM PUMP 11 CONTROL HANDLES 2 LIFT SPOOL VACUUM SWITCH and LOW VACUUM 12 VACUUM GAUGE 3 PAD FRAME WARNING...

Page 8: ...ached to the lifter Then attach the free eye of each lift sling onto the hoisting equipment hook WARNING Hoisting equipment hook must be fitted with restraining latch to prevent lift slings from slipp...

Page 9: ...res Contact Wood s Powr Grip or an authorized dealer for more information While the minimum length and width of the load are determined by the Pad Spread see SPECIFICATIONS the maximum length and widt...

Page 10: ...failure Using the lifter in wet environments may require the operator to take special precautions Moisture on contact surfaces of the load or vacuum pads diminishes the lifter s slip resistance there...

Page 11: ...Performing Inspections and Tests WARNING Always check battery energy before using lifter See MAINTENANCE BATTERY TEST Perform all inspections and tests required by the INSPECTION and TESTING SCHEDULE...

Page 12: ...ATIONS Pad Spread and that they will be loaded evenly while lifting see SPECIFICATIONS Per Pad Load Capacity Then apply the lifter to the load so that all pads are touching the contact surface Sealing...

Page 13: ...case of contamination thoroughly clean the contact surfaces of the load and the vacuum pads see MAINTENANCE VACUUM PAD MAINTENANCE Cleaning and reapply the lifter to the load If the load has rough or...

Page 14: ...n in vacuum to the operator If the pump and warning light turn on while you are lifting a load make sure the vacuum gauge shows a vacuum level of 16 Hg 54 kPa or higher If not move away and stay clear...

Page 15: ...and Load When vacuum indicators show that the lifter is ready use the hoisting equipment to raise the lifter and load as needed to clear any obstacles in their path Use the control handles to keep th...

Page 16: ...ers supplied to keep the vacuum pads clean CE In accordance with CE Standard EN 13155 the lifter is designed to rest on relatively horizontal surfaces without tipping over To store the lifter in this...

Page 17: ...ut of service for 1 month or more Examine the lifter s structure for visual damage Examine the vacuum system including vacuum pads fittings and hoses for visual damage Examine the air filter for condi...

Page 18: ...ERISTICS see INTENDED USE on a stable support Make sure the load is oriented in the upright position 7 2 Apply the vacuum pads to the load as previously directed 3 After the vacuum pump stops running...

Page 19: ...energy registers lower than 50 that is when only red lights are illuminated regardless of the estimated energy requirement WARNING Never use lifter if battery energy is lower than 50 of capacity Whil...

Page 20: ...e battery energy again before operating the lifter see BATTERY TEST preceding VACUUM PAD MAINTENANCE Friction Coefficient The friction coefficient represents the lifter s ability to resist load slippa...

Page 21: ...ess or glaze see REPLACEMENT PARTS LIST Cleaning Regularly clean the face of each vacuum pad to remove oil dust and any other contaminates Acceptable cleaning agents include soapy water and other mild...

Page 22: ...s running leave the pads attached to the surface and interrupt the energy flow from the battery Disconnect the electrical connector uniting the battery to the vacuum generating system Note After the v...

Page 23: ...ment element gaskets 7 and bowl seal for disposal later 5 Clean all other internal parts and the bowl using mild soap and water only Do not use any other cleansing agents 6 Place the new element gaske...

Page 24: ...washer rubber O ring diaphragm and diaphragm retaining screw 4 Reverse the steps above for reassembly as shown Replacing the Head Assembly15 1 Remove the hose fittings from the head assembly and care...

Page 25: ...our head screws 1 and remove the head 2 2 Invert the head and remove the four valve plate screws 9 3 Lift out the valve plate 6 to access the exhaust valve flapper and head gasket 16 4 Remove the exha...

Page 26: ...ped with the Dual Vacuum System have 2 vacuum switches Directions are the same for these lifters except that each vacuum switch must be tested and adjusted individually When you are evaluating vacuum...

Page 27: ...urn the screw counter clockwise when viewing vacuum switch from end with electrical connectors 2 Recheck the vacuum switch setting following each 1 6th turn of the adjustment screw In order to test th...

Page 28: ...7 Amp Hours 1 64590 Battery Gauge 1 64460 Circuit Breaker 15 A 1 64283 Bulb 13 V Bayonet for low vacuum warning light 1 64251 Red Indicator Light 12 V DC aka low vacuum warning light 1 64236 Vacuum Sw...

Page 29: ...se Repairs are required due to abnormal wear and tear The product has been damaged misused or neglected If a problem is not covered under warranty Powr Grip will notify the customer of costs prior to...

Page 30: ...Rev 19 3 9 18 28 VL411LDC 35162...

Page 31: ...Rev 19 3 9 18 29 VL411LDC 35162...

Page 32: ...Rev 19 3 9 18 30 VL411LDC 35162...

Page 33: ...Rev 19 3 9 18 31 VL411LDC 35162...

Page 34: ...Rev 19 3 9 18 32 VL411LDC 35162...

Reviews: