HDMI V2.0 4x1 Presentation Switcher with Audio Extraction
13
l
User-defined EDID
There are four EDID values can be customized by sending the below command.
Note:
When send the below commands to configure EDID, the 4-pin EDID DIP switch
on the rear panel must be in the “1111” status.
Command
Function & Operation
EDIDW[xxxx].
User-defined EDID. [xxxx] = 1011, 1100, 1101 or 1110.
Operation:
Step 1:
Prepare the EDID file (.bin).
Step 2:
Set the 4-pin DIP switch to “1111” status.
Step 3:
Send the command “
EDIDW1101.
”, and the feedback is “
PLEASE SEND
THE EDID FILE!
”.
Step 4:
Send the
EDID file (.bin). If successfully upload, the feedback is:
“
RECEIVED THE FILE, LENGTH=134!