Worx WX156 Original Instructions Manual Download Page 10

10

Lithium-Ion Cordless Drill/Driver 

EN

higher speed and torque with increased 
trigger pressure. Speed is controlled by the 
amount of switch trigger depression. 

WARNING: Do not operate for long 

periods at low speed because 

excess heat will be produced internally.

2. SWITCH LOCK

The switch trigger can be locked in the OFF 
position. This helps to reduce the possibility of 
accidental starting when not in use. To lock the 
switch trigger, place the rotation control in the 
center position.

3. REVERSIBLE (See Fig. C1, C2)

For drilling and screw driving use forward 
rotation marked “

 ” (lever is moved to the 

left). Only use reverse rotation marked “ 

” 

(lever is moved to the right) to remove screws 
or release a jammed drill bit.

WARNING: Never change the 

direction of rotation when the 

chuck is rotating, wait until it has 

stopped!

4. TWO-SPEED GEAR CONTROL 

(See Fig. D)

The drill has a two-speed gear control 
designed for drilling or driving at LO (mark is 
1) or HI (mark is 2) speeds. A slide switch is 
located on top of the drill to select either LO 
or HI speed. When using the drill in the LO 
speed range, the speed will decrease and the 
drill will have greater power and torque. When 
using the drill in the HI speed range, the speed 
will increase and the drill will have less power 
and torque.

Gear I

Low speed range: For screwdriving or working 
with large drilling diameter.

Gear II

High speed range: For working with small 
drilling diameter.

WARNING: To prevent gear damage, 

always allow the chuck to come to 

a complete stop before changing the 

direction of rotation or the two-speed 

gear control.

5. CHUCK ADJUSTMENT (See Fig. E)

To open the chuck jaws rotate the front section 
of the chuck. Insert the drill bit between the 
chuck jaws and rotate the front section in the 
opposite direction. Ensure the drill bit is in 
the center of the chuck jaws. Finally, firmly 
rotate the front chuck section in the opposite 
directions. Your drill bit is now clamped in the 
chuck.

6. TORQUE ADJUSTMENT (See Fig. F)

(Screw driving force of your drill driver)
The torque is adjusted by rotating the torque 
adjustment ring. The torque is greater when 
the torque adjustment ring is set on a higher 
setting. The torque is less when the torque 
adjustment ring is set on a lower setting.
Make the setting as follows:

1 - 4

For driving small screws

5 - 9

For driving screws into soft 
material

10 - 15

For driving screws into soft and 
hard material

For heavy drilling

     

7. AUTOMATIC SPINDLE LOCK 

(See Fig. G)

The automatic spindle lock allows you to use 
it as a regular screwdriver. You can give an 
extra twist to firmly tighten a screw, loosen 
a very tight screw or continue working 
when the battery energy has expired. For 
manual screwdriver purposes, the chuck is 
automatically locked when the tool is off.

8. USING THE SIGHT LIGHT

To turn on the light, press the on/off switch 
and make sure the forward/reverse rotation 
control is on right/left position. When you 
release the on/off switch, the light will be off. 
LED lighting increases visibility-great for 
dark or enclosed area. LED is also a battery 
capacity indicator. It will flash when power 
gets low.

9. DRILLING

When drilling into a hard smooth surface, 
use a center punch to mark the desired hole 

Summary of Contents for WX156

Page 1: ...WX166 1 WX166 2 WX166 3 WX166 4 WX166 5 WX166 6 Lithium Ion Cordless Drill Driver EN RU Liitium ioon juhtmeta trell kruvikeeraja ET Bezvadu litija jonu urbis skr vgriezis LV Li io jon belaidis gr tuv...

Page 2: ...Original instructions EN RU Algsete juhiste t lge ET Ori in lo instrukciju tulkojums LV Originali instrukcij vertimas LT...

Page 3: ...1 2 3 4 5 7 6 8 9...

Page 4: ...A1 A2 B C1 C2 D G E F...

Page 5: ...6 4 WX166 5 WX166 6 1 designation of machinery representative of Cordless Drill WX156 WX156 1 WX156 2 WX156 3 WX166 WX166 1 WX166 2 WX166 3 WX166 4 WX166 5 WX166 6 Voltage 16V Max 20V Max No load spee...

Page 6: ...n good condition and well maintained The use the correct accessory for the tool and ensuring it is sharp and in good condition The tightness of the grip on the handles and if any anti vibration access...

Page 7: ...X166 3 WX156 3 WX166 4 WX166 5 WX166 6 1 3Ah Li ion battery pack 1 2 2 2 0Ah Li ion battery pack 2 1 30 min Charger 1 60 min Charger 1 1 3h Charger 1 1 3 5h Charger Double ended bits 1 1 1 1 1 158pc A...

Page 8: ...th the skin or eyes If contact has been made wash the affected area with copious amounts of water and seek medical advice f Seek medical advice immediately if a cell or battery pack has been swallowed...

Page 9: ...attery charger The Li Ion battery is protected against deep discharging When the battery is empty the machine is switched off by means of a protective circuit The tool holder no longer rotates In a wa...

Page 10: ...te stop before changing the direction of rotation or the two speed gear control 5 CHUCK ADJUSTMENT See Fig E To open the chuck jaws rotate the front section of the chuck Insert the drill bit between t...

Page 11: ...cannot be subject to overload When the load is too high or the allowable battery temperature of 75 C is exceeded the electronic control switches off the power tool until the temperature is in the opti...

Page 12: ...recycle where facilities exist Check with your local authorities or retailer for recycling advice DECLARATION OF CONFORMITY We POSITEC Germany GmbH Konrad Adenauer Ufer 37 50668 K ln Declare that the...

Page 13: ...X156 1 WX156 2 WX156 3 WX166 WX166 1 WX166 2 WX166 3 WX166 4 WX166 5 WX166 6 1 WX156 WX156 1 WX156 2 WX156 3 WX166 WX166 1 WX166 2 WX166 3 WX166 4 WX166 5 WX166 6 16B 20B 0 400 0 1500 15 1 35 40 10 10...

Page 14: ...14 RU LpA 75 A LwA 86 A KpA KwA 3 0 A 80 A EN 60745 ah D 2 06m s2 K 1 5m s ah 2 5m s2 K 1 5m s 10o C...

Page 15: ...WX156 1 WX166 1 WX156 2 WX166 2 1 3Ah Li ion 1 1 2 2 2 2 0Ah Li ion 30 1 1 1 1 1 60 3 3 5 1 1 1 158 1 1 WX166 3 WX156 3 WX166 4 WX166 5 WX166 6 1 3Ah Li ion 1 2 2 2 0Ah Li ion 2 1 30 1 60 1 1 3 1 1 3...

Page 16: ...16 RU 1 2 a b c d e f g h i j k l 20 C 5 C m...

Page 17: ...17 RU n WORX o p q r s...

Page 18: ...18 RU A B A1 6 C A2 1 B 2 3 C1 C2 4 D...

Page 19: ...19 RU 1 2 I II 5 E 6 F 1 4 5 9 10 15 7 G 8 9 HSS...

Page 20: ...20 RU 10 11 30 12 75 C 13 1 2 1 15 3 0 45...

Page 21: ...6 1 WX156 2 WX156 3 WX166 WX166 1 WX166 2 WX166 3 WX166 4 WX166 5 WX166 6 1 2006 42 EC 2004 108 EC 2011 65 EU EN 55014 1 EN 55014 2 EN 60745 1 EN 60745 2 1 EN 60745 2 2 Russell Nicholson Positec Power...

Page 22: ...3 WX166 WX166 1 WX166 2 WX166 3 WX166 4 WX166 5 WX166 6 1 seadme t bit his mis t histab Akudrell WX156 WX156 1 WX156 2 WX156 3 WX166 WX166 1 WX166 2 WX166 3 WX166 4 WX166 5 WX166 6 Nimipinge 16V Max 2...

Page 23: ...akse Kas kasutatakse igeid lisatarvikuid ning veendutakse et t riist on terav ja heas seisundis Kui tugevalt hoitakse k epidemest ning kas kasutatakse vibratsioonivastaseid lisatarvikuid Kas t riista...

Page 24: ...WX156 3 WX166 4 WX166 5 WX166 6 1 3Ah Li ion Aku 1 2 2 2 0Ah Li ion Aku 2 1 30 min Laadija 1 60 min Laadija 1 1 3h Laadija 1 1 3 5h Laadija Kruvikeeraja Otsak 1 1 1 1 1 158pc Tarvikud Me soovitame ost...

Page 25: ...kokkupuutesse naha ja silmadega Kui tekib kokkupuude akuvedelikuga peske kokkupuutekoht rohke veega ja p rduge arsti poole f Kui akuelement v i akupaketi osad on alla neelatud p rduge kohe arsti poole...

Page 26: ...aadijaid Liitium ioon aku on kaitstud liigse t hjenemise eest Kui aku on t hi siis l litub seade kaitsel liti abil v lja t riista hoidja p rlev liikumine peatub Soojas keskkonnas v i p rast intensiivs...

Page 27: ...k asuks padruni haaratsite keskel L petuseks keerake padruni esimene osa vastassuunas tugevalt kinni Teie puuriotsak on n d padrunisse lukustatud 6 P RDEMOMENDI REGULEERIMINE JA L KTRELLI V I PUURI T...

Page 28: ...liti p stiku kohal on asub lukustamise funktsioonil Vabastage edasi ja tagasi suuna l liti pannes selle soovitud suuna asensisse Vajutage p stikut ja trell hakkab p rlema 2 TRELL PEATUB ENNE KRUVI L P...

Page 29: ...X166 3 WX166 4 WX166 5 WX166 6 1 seadme t bit his mis t histab Akudrell Ametikoht Puurimine Vastab j rgmistele direktiividele 2006 42 EC 2004 108 EC 2011 65 EU Vastab standarditele EN 55014 1 EN 55014...

Page 30: ...X166 3 WX166 4 WX166 5 WX166 6 1 ma nas apz m jum nor da uz Bezvadu urbis WX156 WX156 1 WX156 2 WX156 3 WX166 WX166 1 WX166 2 WX166 3 WX166 4 WX166 5 WX166 6 Spriegums 16V Max 20V Max trums bez slodze...

Page 31: ...bti materi li ier ce ir lab st vokl un tiek labi uztur ta ier cei tiek izmantots atbilsto s piederums p rliecinoties ka tas ir ass un lab st vokl satv riena bl vums pie rokturiem un antivibr cijas pie...

Page 32: ...56 3 WX166 4 WX166 5 WX166 6 1 3Ah Li ion akumulatora bloks 1 2 2 2 0Ah Li ion akumulatora bloks 2 1 30 min l d t js 1 60 min l d t js 1 1 3h l d t js 1 1 3 5h l d t js Skr vgrie a uzgalis 1 1 1 1 1 1...

Page 33: ...aujiet idruma non k anu saskar ar du vai ac m Ja ir notikusi saskare skalojiet cietu o vietu ar lielu daudzumu dens un mekl jiet medic nisku pal dz bu f Nekav joties mekl jiet medic nisko pal dz bu ja...

Page 34: ...to Li jonu akumulatoru Nelietojiet citu akumulatora l d t ju is Li jonu akumulators ir aizsarg ts no piln gas izl d anas Kad akumulators ir izl d jies aizsargsh ma izsl dz elektroier ci R ka tur t js...

Page 35: ...u zobp rnesuma mai as pagaidiet l dz patrona piln gi apst jas 5 PATRONAS REGUL ANA E Att Lai atv rtu patronas spailes pagrieziet patronas priek jo da u Ievietojiet urbja uzgali patronas spail s un pag...

Page 36: ...AS ATKAR GA P RSLODZES AIZSARDZ BA Lietojot elektroinstrumentu k paredz ts to nevar pak aut p rslodzei Ja slodze ir p r k liela vai akumulatora temperat ra p rsniedz 75 C elektronisk vad ba izsl dz el...

Page 37: ...nsult jieties ar viet j m iest d m vai p rdev ju ATBILST BAS DEKLAR CIJA M s POSITEC Germany GmbH Konrad Adenauer Ufer 37 50668 K ln Pazi ojam ka prece Apraksts WORX Bezvadu litija jonu urbis skr vgri...

Page 38: ...4 WX166 5 WX166 6 1 renginio ym jimas Belaidis gr tuvas pavyzdys WX156 WX156 1 WX156 2 WX156 3 WX166 WX166 1 WX166 2 WX166 3 WX166 4 WX166 5 WX166 6 Nominali tampa 16V Max 20V Max Nominalus s ki skai...

Page 39: ...s yra geros b kl s ir gerai pri i rimas Tinkam rankio pried naudojimas ir u tikrinimas kad jis b t a trus ir geros b kl s Ranken su mimo tvirtumas ir ar naudojami apsaugos nuo vibracijos priedai Be to...

Page 40: ...WX156 3 WX166 4 WX166 5 WX166 6 1 3Ah Li ion Maitinimo element pakuot 1 2 2 2 0Ah Li ion Maitinimo element pakuot 2 1 30 min Keitiklis 1 60 min Keitiklis 1 1 3h Keitiklis 1 1 3 5h Keitiklis Atsuktuvo...

Page 41: ...s stenkit s kad jo nepatekt ant odos ir akis Kontakto atveju gausiai plaukite pa eist viet dideliu kiekiu vandens ir kreipkit s gydytoj f Jeigu prarytum te maitinimo element arba i gertum te akumuliat...

Page 42: ...S KROVIMAS Pateiktas elemento kroviklis pritaikytas rankyje montuotam li io jon elementui Nenaudokite kito element kroviklio Li io jon elementas apsaugotas nuo visi ko i sekimo Kai elementas i sek s...

Page 43: ...kimosi krypt arba dviej grei i pavar 5 LAIKIKLIO REGULIAVIMAS r E Jei norite atidaryti laikiklio iotis pasukite priekin laikiklio dal Tarp gr tuvo io i ki kite gr t ir priekin dal pasukite prie inga k...

Page 44: ...kis atv st 12 APSAUGA NUO PERKAITIMO Naudojant pagal numatyt j paskirt is elektrinis rankis negali b ti perkrautas Kai apkrova yra pernelyg didel arba akumuliatoriaus temperat ra vir ija 75 C elektron...

Page 45: ...mis Jei turite galimyb perdirbkite jas Patarimo d l perdirbimo kreipkit s vietinius specialistus ar atstov ATITIKTIES DEKLARACIJA Mes POSITEC Germany GmbH Konrad Adenauer Ufer 37 50668 K ln Parei kiam...

Page 46: ......

Page 47: ......

Page 48: ...Copyright 2015 Positec All Rights Reserved 2CDT45QPK11004A0 www worx com...

Reviews: