WARNING: 

This product can expose you to 

chemicals including lead, phthalate or bisphenol 

A which are known to the State of California to cause 

cancer, birth defects or other reproductive harm. 

Wash your hands after use. 

For more information 

go to www.P65Warnings.ca.gov.

SAFETY INSTRUCTIONS

WARNING!

 User must read the product 

manual to fully understand this product prior to 

use, and follow all safety instructions as outlined in 

the WORXAIR

TM

 Operator’s Manual.

CAUTION!

The user must wear the appropriate 

clothing and safety goggles when operating 

this product. Be aware of all bystanders, pets and 

objects in a close proximity.

•  

DO NOT

 operate blower and attachments when 

fatigued.

•  

DO NOT

 overreach or stand on unstable support. 

Keep good footing and balance at all times.

•   Never direct airflow towards bystanders. Always 

be aware of the direction that the debris will be 

thrown.

•   Use a face filter mask to avoid breathing dust and 

debris.

ASSEMBLY AND OPERATION

1. ATTACH THE GUTTER KIT AS SHOWN IN 

Fig. A:

Connect the (1, 2, 3) components by screwing 

together. Snap the (3, 4) components together. 

2. ASSEMBLING THE UNIVERSAL ADAPTER

1)  Place the fabric side of the Universal Adapter 

over the Blower Outlet and slide it on as far as 

possible (B1.1).

 

WORX TURBINE

TM

 models 

- Place the fabric 

side of the Universal Adapter over the outlet 

of the Fan Housing and slide it on as far as 

possible(B1.2).

 

Previous WORX TRIVAC

TM

 models 

(WG500.2/WG505/WG509)

 - Place the fabric 

side of the Universal Adapter over the Vacuum 

Outlet and slide it on as far as possible (B1.3). 

Before operation, flip the blow/vac switch into the 

vacuum mode.

 

PLEASE NOTE: 

Items can be vacuumed through 

the vac inlet and pass through or become 

clogged within the gutter kit. Please keep the vac 

inlet away from objects while using the gutter kit.

 

WORX TRIVAC

TM

 models  (WG512, WG513, 

WG514 ) - 

i.  Attach the adapter for TRIVAC

TM

 models (WG512, 

WG513, WG514) directly into the vacuum outlet 

(dust extraction port). (See B1.4)

ii.  Place the fabric side of the Universal Adapter 

over  the TRIVAC

TM

 adapter and slide it on as far 

as possible. Before operation, flip the blow/vac 

switch into the vacuum mode. (See B1.5)

WORX TURBINE FUSION

TM

 models - 

i.  Attach the Adapter for Turbine Fusion with the 

Fan Housing and turn the Adapter to the right 

position according to the position as the arrow 

shown on the Adapter. (B1.6)

ii.  Place the fabric side of the Universal Adapter 

over the Adapter for Turbine Fusion and slide it on 

as far as possible. (B1.6)

iii. 

PLEASE NOTE: 

Only operate the 

TURBINEFUSION in Blow mode. Please remove 

the collection bag before operating.

2)  Check to make sure the strap is threaded through 

the locking mechanism. Then pull to tighten the 

strap (B2). Increase the tension by pulling the 

latch up and down to tighten (B3).  To loosen, 

simply press the two outside latches down and 

then pull the strap out from other side (B4).

3)  Test that the Universal Adapter will not slide off 

of the blower outlet.

4)  If further tightening is needed, then pull the 

middle latch up and down until the adapter is 

tight.  Please recheck if it will slide off of the 

blower outlet. Realign and repeat these steps 

if needed (B3).  To loosen, simply press the two 

outside latches down and then pull the strap out 

from other side (B4).

PLEASE NOTE: 

The Universal Adapter may have 

space between the Blower Outlet and Adapter Outlet 

after installation. 

To remove the adapter, simply press the two outside 

latches down and loosen the strap to remove it from 

the Blower Outlet (B4).

NOTE:

Use only enough Gutter Tube Extensions to 

comfortably reach the inside of the gutter.

3. OPERATE ACCORDING TO Fig. C: 

The Gutter Tube Nozzle can be adjusted to any 

desired direction by rotating the Gutter Tube 

Connecter as shown in Fig. D. Gutter cleaning 

applications will vary. It is recommended to try 

various positions to find the most effective working 

position for the type of house and gutter design.

Summary of Contents for GUTTERPRO WA4094

Page 1: ...GUTTERPRO Universal Gutter Cleaning Kit EN Trousse de nettoyage de gouttières GUTTERPRO F Kit de limpieza de canales GUTTERPRO ES P03 P06 P08 WA4094 ...

Page 2: ...ts all brands of blower vacs up to 5 in diameter S adapte à toutes les marques de souffleurs aspirateurs de 5 de diamètre Sirve para todo tipo de extractores aspiradoras de hasta de 5 de diámetro 12 7 cm ...

Page 3: ...tter Cleaning Kit 1 GUTTER TUBE NOZZLE QUANTITY OF 1 2 GUTTER TUBE EXTENSION QUANTITY OF 3 3 GUTTER TUBE ADAPTER QUANTITY OF 1 4 UNIVERSAL ADAPTER 5 TURBINEFUSIONTM ADAPTER 6 ADAPTER FOR TRIVACTM WG512 WG513 WG514 1 2 2 2 3 4 5 6 ...

Page 4: ...EN 4 GUTTERPRO Universal Gutter Cleaning Kit 1 2 2 3 4 2 3 1 2 B4 A C B1 1 B1 3 B1 6 B1 4 B1 5 B3 D B2 B1 2 ...

Page 5: ...G512 WG513 WG514 i Attach the adapter forTRIVACTM models WG512 WG513 WG514 directly into the vacuum outlet dust extraction port See B1 4 ii Place the fabric side of the Universal Adapter over theTRIVACTM adapter and slide it on as far as possible Before operation flip the blow vac switch into the vacuum mode See B1 5 WORX TURBINE FUSIONTM models i Attach the Adapter forTurbine Fusion with the Fan ...

Page 6: ...ant ensemble Cliquez les pièces 3 et 4 en place 2 Montage du Adaptateur Universel 1 Placez la section de tissus de l adaptateur universel sur le col de la sortie du souffleur et glissez le le plus loin possible B1 1 Modèles WORX TURBINETM Placez le côté tissu de l adaptateur universel sur la sortie du boîtier de ventilateur et glissez le dessus autant que possible B1 2 Anciens modèles WORX TRIVACT...

Page 7: ...nouveau s il glissera sur le col du souffleur Réalignez et répétez ces étapes au besoin B3 Pour desserrer pressez simplement les deux attaches extérieures B4 VEUILLEZ NOTER L adaptateur universel peut avoir un certain jeu entre la sortie du souffleur et la sortie de l adaptateur suite à l installation Pour retirer l adaptateur pressez simplement les deux attaches extérieures et relâchez la courroi...

Page 8: ...ra del adaptador universal sobre la salida de la soplador y deslícelo lo más lejos posible B1 1 Modelos WORX TURBINETM Coloque el lado de tela del Adaptador Universal sobre la salida del Alojamiento del ventilador y deslícelo lo más posible B1 2 Modelos WORX TRIVACTM anteriores WG500 2 WG505 WG509 coloque el lado de la tela del adaptador universal en la salida de la aspiradora y deslícelo lo más l...

Page 9: ...que el adaptador esté ajustado Vuelva a comprobar que no se deslizará y extraerá de la salida de la soplador Vuelva a alinear y repita estos pasos si es necesario B3 Para aflojar simplemente presione los 2 pestillos exteriores B4 Nota El adaptador universal podría tener un espacio entre la salida de la soplador y la salida del adaptador después de la instalación Para extraer el adaptador simplemen...

Page 10: ......

Page 11: ......

Page 12: ...Copyright 2018 Positec All Rights Reserved Copyright 2018 Positec Tous droits réservés Derechos reservados 2018 Positec Todos los derechos reservados AR01396000 www worx com ...

Reviews: