60
Parameters:
basename, channel, terminal, line, position, prompt, shifted, timestamped
Function:
This instructs the terminal attached to client
basename
on channel to display the prompt at line and posi-
tion and wait for data to be entered from the terminal keypad only. If shifted is set to "true", the terminal
will start in shifted mode. Timestamped appends a (hhmmss) prefix to the returned data.
InputScanner
Parameters:
basename, channel, terminal, line, position, prompt, allowbreakout, timestamped
Function:
This instructs the terminal attached to client
basename
on channel to display the prompt at line and posi-
tion and wait for data to be entered from the terminal scanner only. Setting
allowbreakout
to true allow
user to "breakout" of scanner only mode by pressing the end key on the terminal. A CR will be
sent to the host.
InputYesNo
Parameters:
basename, channel, terminal, line, position, prompt
Function:
This instructs the terminal attached to client
basename
on channel to display the prompt at line and posi-
tion and wait for a Yes (Enter key or C key) or a No (0 key or B key) from the terminal keypad.
Note: C and B keys are used to facilitate keypad entry while scanning with the integrated laser.
InputPassword
Parameters:
basename, channel, terminal, line, position, prompt, shifted
Function:
This instructs the terminal attached to client
basename
on channel to display the prompt at line and posi-
tion and wait for data to be entered from the terminal keypad only. The entered data is not displayed on
the terminal.
InputSerial
Parameters:
basename, channel, terminal, line, position, prompt
Function:
This instructs the terminal attached to client
basename
on channel to display the prompt at line and posi-
tion and wait for data to be received through the terminal serial port. Waiting for serial input can be by-
passed by pressing the enter key on the terminal which will send an empty data string to the host (fires the
OnTermData
event handler).
OutputSerial
Parameters:
basename, channel, terminal, data
Function:
This instructs the terminal attached to client
basename
on channel to send data to the terminal’s serial
port. Data must be
less than 231 characters in length for each call to
OutputSerial
.
SendDisplay
Parameters:
basename, channel, terminal, line, position, prompt
Function:
This instructs the terminal attached to client
basename
on channel to display the prompt at line and posi-
tion. Must be followed by an "
Input
" method call to take effect.
ClearScreen
Parameters:
basename, channel, terminal
Function:
This instructs the terminal attached to client
basename
on
channel
to clear its display. Must be followed
by an "
Input
" method call to take effect.
ClearLine
Parameters:
basename, channel, terminal, line
Function:
This instructs the terminal attached to client
basename
on
channel
to clear the specified line on its dis-
play. Must be followed by an "
Input
" method call to take effect.
SendDate
Parameters:
basename, channel, terminal, line
Function:
This instructs the terminal attached to client
basename
on
channel
to display date and time on the speci-
fied line number. Must be followed by an "Input" method call to take effect.
Beep
Parameters:
basename, channel, terminal, count
Function:
This instructs the terminal attached to client
basename
on
channel
to beep count times. Count may be a
value from 1 to 9. Must be followed by an "Input" method call to take effect.
PlayVoice
Parameters:
basename, channel, terminal, msgnum
Summary of Contents for 7100 RF Terminal Series