■ Do not weld on drums, tanks, or any closed containers unless a qualified person has tested it and
declared it or prepared it to be safe.
■ Connect the work cable to the work as close to the welding area as practical. Work cables connected
to the building framework or other locations away from the welding area increase the possibility of
the welding current passing through lifting chains, crane cables or other alternate circuits. This can
create fire hazards or overheat lifting chains or cables until they fail.
■ INSTALLATION
● The welding machine shall be installed at a place ;
․
free from the inflammables
․
less humidity, dirt and dust
․
protecting from influence of direct sunlight, wind and rain
․
not generated oil vapor and corrosive gas
․
operating temperature range is from -10℃ to 40℃
․
least 30㎝ away from wall and other welding machine
● Input Connection (Rear of the machine)
Be sure the voltage, phase and frequency of the input power is as specified on the name plate
located on the rear panel of the machine.
․
To connect the power cables, turn the power switch OFF
․
Verify the voltage to be supplied from main power.
․
Open the cover of terminal plate and connect the power cable to the power input terminal on the rear of
the machine and close the cover of terminal plate.
․
Recommended cable specification
Item
Unit
200LD
200LD2/3
230LD
250LD3
300LD3
400LD3
500LD3
Input cable
㎟
5.5
8
Holder cable
25
38
50
Earth cable