NAME
Access (R/W)
Possible value on the serial port
of the unit
Comments
CONF.VSWR_TRIG
R/W
"WARNING" or "FAULT/WARN" or
"FAULT"
Working mode in case of VSWR overshoot.
WARNING = triggers a simple Warning.
WARN/FAULT = triggers a fault but does not
trigger the reflected protection. FAULT =
triggers a fault and the reflected protection
triggers a VSWR fault. Default value: FAULT
CONF.VSWRTRIP *
R/W
"ON" or "OFF"
Enables/disables reflected power safety
7.2.5.
Alarm commands
Greyed out commands are Ecreso FM only commands.
Commands in bold are Ecreso FM Amplifier and Ecreso FM with integrated amplifier (300 W to 2000 W) only
commands.
Commands followed by two stars (**) are available with modules sold in v.1.2.2 or higher.
NAME
Access
(R/W)
Possible value on the serial port
of the unit
Comments
ALARM.10MSWITCH
R
"ON" or "OFF"
Indicates there was a 10 MHz switch
ALARM.1DB
R
"ON" or "OFF"
ON =>1 dB Alarm, OFF => => No alarm
ALARM.3DB
R
"ON" or "OFF"
ON =>3 dB Alarm, OFF => => No alarm
ALARM.AMB
R
"ON" or "OFF"
ON => ambient alarm, OFF => No alarm.
ALARM.BATLOW
R
"ON" or "OFF"
Indicates if the NVRAM battery’s level is OK
ALARM.COMM
R
"ON" or "OFF"
Indicates if there is a communication fault with one
of the units of the system
ALARM.CUR1
R
"ON" or "OFF"
Indicates the PSU 1 current is over the max
threshold.
ALARM.CUR2
R
"ON" or "OFF"
Indicates the PSU 2 current is over the max
threshold. (1500 & 2000 W modules only)
ALARM.CUR3
R
"ON" or "OFF"
Indicates the PSU 3 current is over the max
threshold. (2000 W modules only)
ALARM.CUR4
R
"ON" or "OFF"
Indicates the PSU 4 current is over the max
threshold. (2000 W modules only)
ALARM.EXC_TEMP
R
"ON" or "OFF"
ON => indicates the temperature of the exciter is
higher than the max threshold
ALARM.FAN1
R
"ON" or "OFF"
Fan 1 alarm; speed is too slow
ALARM.FAN2
R
"ON" or "OFF"
Fan 2 alarm; speed is too slow
ALARM.FAULT
R
"ON" or "OFF"
ON => critical alarm OFF => => No alarm (3 dB,
VSWR)
ALARM.INT_TEMP **
R
"ON" or "OFF"
ON => indicates the temperature of the internal
sensor is higher than the max threshold
ALARM.HEAT1
R
"ON" or "OFF"
ON => radiator temp alarm, OFF => No alarm.
ALARM.HEAT2
R
"ON" or "OFF"
ON => radiator temp alarm, OFF => No alarm.
(1500 & 2000 W modules only)
ALARM.HEAT3
R
"ON" or "OFF"
ON => radiator temp alarm, OFF => No alarm.
(2000 W modules only)
ALARM.HEAT4
R
"ON" or "OFF"
ON => radiator temp alarm, OFF => No alarm.
(2000 W modules only)
ALARM.INPUT_FAULT
R
"ON" or "OFF"
Indicates if there is an alarm on an input seta as
FAULT
ALARM.INPUTSWITCH
R
"ON" or "OFF"
Indicates if the current audio input corresponds to
the highest priority channel
ALARM.LINE1
R
"ON" or "OFF"
ON => no signal on the input LINE1
ALARM.LINE2
R
"ON" or "OFF"
ON => no signal on the input LINE2