A.3.3.

 

Readings  

 

Readings table 

 

 

 

This part lists the various readings performed by the DAB Probe. 
It indicates the name of the reading, its unit and the factor to apply (if any). 

 

Name 

Syntax 

Access 

GET - Possible value(s) 

OID 

readingsNameColumnId 

STRING 

N/A 

Index of the measurement: 0 to 7  
(number of collected RF measurements) 

 

readingsName 

STRING 

Read Only 

Measurement Type 

.1.3.6.1.4.1.5299.15.29.1.8.3.1.1.2.measureIndex  

readingsNameUnit 

STRING 

Read Only 

Unit and factor of the measurement 

.1.3.6.1.4.1.5299.15.29.1.8.3.1.1.3.measureIndex  

 

 

Readings values table 

 
 

 
 

This part gives the values of the RF readings performed by the DAB Probe (including factor when applicable). 

 

Name 

Syntax 

Access 

GET - Possible value(s) 

OID 

readingsValuesRowId 

INTEGER 

N/A 

0 (index of the 1

st

 MUX)  

to x (last monitored MUX) 
(See Channel table) 

 

readingsValuesColumnId 

INTEGER 

N/A 

Index of the measurement: 0 to 7  
(number of collected RF measurements) 

 

readingsValues 

INTEGER 

Read Only 

Value of the measurement (including factor) 

.1.3.6.1.4.1.5299.15.29.1.8.3.2.1.3.channelIndex.measureIndex 

 

 

 

Summary of Contents for AUDEMAT DAB PROBE01

Page 1: ...WorldCast Systems web www worldcastsystems com e mail contact worldcastsystems com AUDEMAT DAB PROBE USER MANUAL SOFTWARE VERSION 2 1 X Date 2019 06 27 Audemat is a registered trademark...

Page 2: ...THE AUDEMAT DAB PROBE 10 3 1 Connecting to the network 10 3 2 Configuring the AUDEMAT DAB PROBE using the embedded website 11 3 2 1 Connecting to the web site 11 3 2 2 Selecting channels to monitor 1...

Page 3: ...2 System IP Settings 31 5 8 3 System SNMP SMTP 32 5 8 4 System Users 34 APPENDIX A HOW TO USE SNMP COMMANDS WITH THE AUDEMAT DAB PROBE 36 A 1 Download the MIB file from the AUDEMAT DAB Probe unit 36...

Page 4: ...esearch Development and its innovative approach has been repeatedly recognized by the industry Our products have been selected to receive awards for innovation at consecutive NAB Shows for over 13 yea...

Page 5: ...PROBE ScriptEasy SNMP allows communication with 10 additional units using the SNMP protocol and the ScriptEasy software communication with 10 units is possible as standard ScriptEasy Driver License d...

Page 6: ...al network is not stable a power conditioner such as a UPS must be used The device must only be used with a plug that incorporates a protective ground contact To avoid any risk of electrocution the pr...

Page 7: ...ype Left Right digital 1 XLR type AES headphone 6 35 mm SD card slot 1 For measurement history storage Telemetry Includes ScriptEasy software Relays 8 SPDT 1 A 30 V Digital inputs 16 Internal or exter...

Page 8: ...ion interfaces ETI NI output ETS 300 799 o included in the ensemble structure monitoring 2 2 Network configuration This unit does not deal with network related security issues It is up to the user to...

Page 9: ...in the box 1 power supply cable 1 Ethernet cable 1 folder including 1 quick start notice 2 4 Front panel Future use Indicators CPU LED blinks to indicate CPU activity Critical Major Minor LEDs On when...

Page 10: ...he menu Use the arrow to select the System menu and touch the Check button The Network menu is selected touch the Check button Use the arrow to select the Configuration menu and touch the Check button...

Page 11: ...from one browser to another For optimal performances Google Chrome is recommended The browser may display a message indicating that the connection is not certified however the site is secured data is...

Page 12: ...M tropole France 33 0 5 57 928928 contact worldcastsystems com www worldcastsystems com 3 2 3 Viewing channel status and readings 1 Select one of the monitored channels in the list 2 For that channel...

Page 13: ...ting parameters and adjusting values LEDs indicate possible directions for instance only up and down arrows are available when scrolling through main menus When adjusting values press on the top or do...

Page 14: ...Armstrong 33700 Merignac Bordeaux M tropole France 33 0 5 57 928928 contact worldcastsystems com www worldcastsystems com The status screen is the default screen Push the Check button to display first...

Page 15: ...Manual 06 2019 Page 15 WorldCast Systems SAS 20 avenue Neil Armstrong 33700 Merignac Bordeaux M tropole France 33 0 5 57 928928 contact worldcastsystems com www worldcastsystems com 4 3 4 2 Configurat...

Page 16: ...unicates with the outside world via the IP network It comes with a client server application serving as graphic user interface that makes it possible to remotely configure the unit view measurements a...

Page 17: ...rror free for 2 consecutive cycles The hysteresis is an additional factor to be taken into account before the unit returns to normal state after a level type threshold violation This value adjusts the...

Page 18: ...is monitored for a set time 5 seconds on the example above with a 2 second delay before alarm Recorded start and end times depend in part on the monitoring cycle Channel 1 the error starts second 2 wh...

Page 19: ...that the connection is not certified however the site is secured data is encrypted and you may proceed to access it To prevent these potential blocking and warning messages WorldCast Systems now supp...

Page 20: ...rameters have been modified Before saving values are temporarily memorized even when navigating to another page Connect disconnect and change language Information on the application The left menu is v...

Page 21: ...icates the currently monitored channel Color indicators give the status of each channel OK In error In alarm The selected channel is highlighted in blue That s the channel for which information is dis...

Page 22: ...rameters with alarm status and readings OK In alarm In error Not monitored 4 List of services Audio status for each service OK In alarm Not monitored play audio This action will lock the receiver and...

Page 23: ...rval is always positioned with the method of the first echo The delay is given in seconds its equivalent in km is also indicated Constellation 2 dimensional representation of the signal giving indicat...

Page 24: ...tsystems com 5 5 4 FIG tables decoding Fast Information Group indicates additional information is available 5 5 5 History measurements This page displays the history of RF Measurements for the selecte...

Page 25: ...ered when the channel was created as needed Select the monitoring mode Date RF dBm SNR dB CNR dB MER dB FOffset kHz 11 16 2018 08 39 00 10 26 6 46 36 6 1 4 11 16 2018 08 40 00 10 26 5 46 1 36 5 1 4 11...

Page 26: ...itoring check parameters you want to monitor display additional options explained section 5 2 2 o Time out before alarm o Hysteresis o Intermittent error max number allowed in the time window o Interm...

Page 27: ...castsystems com 6 Monitoring of structure changes and audio associated with services Set the threshold and the delay before alarm as for other parameters To monitor the service structure first set the...

Page 28: ...to automatically detect channels 2 Manually configure a channel select the channel enter its name and click the Create button A manually configured channel is directly added to the monitoring list On...

Page 29: ...181 936 MHz Alarm Start Current 82 reference 50 21 11 2018 09 18 14 CET N A Configuration Changed 21 11 2018 09 18 06 CET N A Delete channel User action 21 11 2018 09 18 04 CET N A Configuration Chang...

Page 30: ...ication which gives access to a status and control dashboard of your unit A default view is available it can be modified and more can be created Custom views are based on the ScriptEasy script Read th...

Page 31: ...s available you may receive the update patch file from your WorldCast Systems dealer Click the Select button to locate it and once selected click the Apply button After the upload process is done chec...

Page 32: ...configuration pages Authority Certification To prevent potential blocking and warning messages WorldCast Systems now supplies certificates for HTTPS browsing Download the certificate Display the adva...

Page 33: ...is sent n times Number of repeats and stored in a queue If the trap is acknowledged it is deleted from the queue If the trap is not acknowledged it will be sent up to m times Max attempts in a t dela...

Page 34: ...ows the user to customize the first parts of the alarm e mails to be more compatible with portable devices List of available keywords Name Description Can be inserted in the subject of the mail Can be...

Page 35: ...ton In the user window enter modify required information You may change login names but make sure each is unique Enter the user email It will be used to send trap notifications Set the minimum severit...

Page 36: ...tsystems com APPENDIX A HOW TO USE SNMP COMMANDS WITH THE AUDEMAT DAB PROBE A 1 Download the MIB file from the AUDEMAT DAB Probe unit Connect to the unit and go to the System menu In the SNMP SMTP sub...

Page 37: ...robe with its software hardware version serial number Name Syntax Access OID sysconfigRevision STRING Read Only 1 3 6 1 4 1 5299 15 29 1 1 0 sysSystemName STRING Read Write 1 3 6 1 4 1 5299 15 29 1 2...

Page 38: ...4 channelindex channelmonitoringStartTime INTEGER Read Write N A future use 1 3 6 1 4 1 5299 15 29 1 8 1 1 5 channelindex channelmonitoringEndTime INTEGER Read Write N A future use 1 3 6 1 4 1 5299 15...

Page 39: ...armsAlarmID INTEGER N A 0 to 15 number of possible alarm types See Alarms table currentAlarmsValue STRING Read Only 1 Alarm declared 1 3 6 1 4 1 5299 15 29 1 8 2 1 3 channelIndex alarmIndex CurrentAla...

Page 40: ...ts readingsName STRING Read Only Measurement Type 1 3 6 1 4 1 5299 15 29 1 8 3 1 1 2 measureIndex readingsNameUnit STRING Read Only Unit and factor of the measurement 1 3 6 1 4 1 5299 15 29 1 8 3 1 1...

Page 41: ...ess GET Possible value s OID tiiCurrentChannelId INTEGER N A 0 index of the 1st MUX to x last monitored MUX See Channel table tiiCurrentId INTEGER N A 0 to 4 max number of monitored tii 5 tiiCurrentMa...

Page 42: ...monitored MUX See Channel table sfnCurrentPeakId INTEGER N A 0 to 4 max number of monitored Tx peak 5 sfnCurrentPos INTEGER Read Only Reception time shift of the peak s compared to the main peak 1 3 6...

Page 43: ...64 channel IDs alarmsValuesValue INTEGER Read Only 0 no monitored 1 status OK 2 alarm detected 3 Alarm declared 1 3 6 1 4 1 5299 15 29 1 8 6 2 1 3 ChannelIndex SubChannelID Note for audio alarms SubCh...

Page 44: ...stsystems com www worldcastsystems com A 4 Settings This part of the MIB describes the configuration of the alarm thresholds for the RF monitored parameters RF level low1 threshold low2 threshold high...

Page 45: ...5 29 1 8 7 5 1 item channelID Item item to configure for this parameter active monitoring 2 threshold 3 hysteresis 4 Item value from 2 to 10 Channel ID index of the MUX from 0 to max MUX 1 cnrLevelLow...

Page 46: ...Channel ID index of the MUX from 0 to max MUX 1 A 5 Mutiplex A 5 1 Ensemble Table Name Syntax Access GET Possible value s OID ensembleID INTEGER Read Only Identifier of the MUX in decimal 1 3 6 1 4 1...

Page 47: ...4 1 5299 15 29 1 9 3 1 7 ChannelID ServiceID SubChannelID Componentdty INTEGER Read Only 1 3 6 1 4 1 5299 15 29 1 9 3 1 8 ChannelID ServiceID SubChannelID componentappNb STRING Read Only 1 3 6 1 4 1...

Page 48: ...astsystems com A 5 4 Audio measure Table Name Syntax Access GET Possible value s OID audioMeasurelevelL INTEGER Read Only Audio Left level for the service 1 3 6 1 4 1 5299 15 29 1 9 4 1 3 channelIndex...

Page 49: ...stsystems com www worldcastsystems com APPENDIX B FOR FURTHER INFORMATION Please contact Head office WorldCast Systems 20 avenue Neil Armstrong 33700 MERIGNAC Bordeaux M tropole FRANCE Tel 33 0 557 92...

Reviews: