Page 13
Use only your hand to push in or turn the gas control knob. Never use tools.
If the knob will not push in or turn by hand, don’t try to repair it, call qualified
service technician or gas supplier. Force or attempted repair may result in a fire
or explosion.
Do not use this appliance if any part has been under water. Immediately call
a qualified service technician to inspect the appliance and replace any part of
the control system and any gas control component which has been under water.
LIGHTING INSTRUCTIONS:
1. Read the aforementioned safety information.
2. Make sure manual shutoff valve is fully open.
3. Push in gas control knob slightly and turn clockwise to the OFF
position.
4. Wait five minutes to clear any gas. Then smell for gas, including near the
floor. If you smell gas, follow the safety information on the front page. If you
don’t smell gas, go to the next step.
5. Push in gas control knob slightly and turn counterclockwise to
"PILOT/IGN" and depress for five(5) seconds.
NOTE : The first time that the heater is operated after connecting the gas
supply, the control knob should be depressed for about thirty(30) seconds. This
will allow, air to bleed from the gas system.
6. Release control knob pressure and turn clockwise to "OFF".
7. Depress control knob while OFF, then turn back to PILOT/IGN.
This should cause the spark from the piezo ignitor to light the pilot gas.
Keep control knob depressed for ten(10) seconds before releasing. If pilot does
not light, repeat steps 5, 6 and 7 or use a match.
8. To select the heating level desired, partially press down the control slightly and
rotate counterclockwise .
Release the downward Pressure on the knob while continuing to turn until the
knob locks at the desired setting position. Do not operate between the locked
position.
Summary of Contents for Kozy-World KWN181
Page 21: ...Page 21 PARTS LIST...