2015 World Cat 320CC Owners Manual
pump feeds the pull out shower located on the aft transom wall, freshwater wiper rinse and the marine head. To view
the layout of the water systems see the drawing in section 10.4.7.
10.1.5
Seacocks
OPEN
CLOSED
Ball valves (seacocks) are installed on the water intake for both the livewell and raw water system. The seacock must
be in the open position for these systems to work. When open, the handle will be parallel to the valve. In the closed
position the handle is perpendicular to the valve (see picture above). World Cat recommends that the seacocks remain
in the closed position when not in use, or when the boat is left unattended to prevent the vessel from taking on water
due to a plumbing failure.
10.1.6
Livewell System
Your 320CC has a 42-gallon livewell system which is supplied by a dual purpose livewell pump. The pump is located
in the port bilge compartment and can be reached through the inspection port in the motorwell. The wiring is secured
to the pump using a tie-strap, and must be disconnected prior to removing the pump.
The livewell pump draws water through the strainer mounted on the inboard side of the port sponson. A seacock is
installed between the pickup and the pump to allow you to seal the system between use, or in the event of a plumbing
failure.
To operate the livewell, first verify that the seacock is open, then check the y-valve located in the rigging space
beneath the livewell. To access this area, use the inspection hatch located on the starboard vertical wall of the helm
leaning post. The valve allows you to choose between the overflow drain for normal operation, and the end of day
drain for residue removal and final draining. When you have completed these steps, engage the livewell pump using
the switch at the dash. Water will fill the tank until it is level with the overboard drain, which evacuates water through
the hullside. To clear bait residue from the tank during operation, temporarily change the orientation of the y-valve.
When you have finished using the livewell, remove the water by changing the y-valve to select the lower drain.
NOTICE
While underway, leaving your livewell seacock open could result in inadvertently filling your livewell.
To prevent this, close the seacock when the pump is not in operation.
NOTICE
Operating the engines in reverse can cause excessive ventilation near the livewell intake, causing the
Page 10-57
Summary of Contents for 320CC 2015
Page 1: ...2015 OWNER S MANUAL 320CC ...
Page 11: ...2015 World Cat 320CC Owners Manual 3 2 320CC FEATURES LIST Page 3 10 ...
Page 42: ...2015 World Cat 320CC Owners Manual 7 5 UPHOLSTERY CARE OPTIONAL SOLID UPHOLSTERY Page 7 41 ...
Page 43: ...2015 World Cat 320CC Owners Manual Page 7 42 ...
Page 47: ...2015 World Cat 320CC Owners Manual Page 7 46 ...
Page 48: ...2015 World Cat 320CC Owners Manual Page 7 47 ...
Page 49: ...2015 World Cat 320CC Owners Manual Page 7 48 ...
Page 50: ...2015 World Cat 320CC Owners Manual Page 7 49 ...
Page 52: ...2015 World Cat 320CC Owners Manual Chapter 8 HURRICANE PREPAREDNESS Page 8 51 ...
Page 53: ...2015 World Cat 320CC Owners Manual Page 8 52 ...
Page 54: ...2015 World Cat 320CC Owners Manual Page 8 53 ...
Page 65: ...2015 World Cat 320CC Owners Manual 10 4 3 Console Wiring Diagram Page 10 64 ...
Page 69: ...2015 World Cat 320CC Owners Manual 10 4 7 Water Systems Diagram Page 10 68 ...
Page 70: ...2015 World Cat 320CC Owners Manual 10 4 8 Thru Hull Diagram Page 10 69 ...